036-21489-001-C-1004
TABLE 3: COOLING CAPACITIES - 20 TON
AIR ON
EVAPORATOR
COIL
TOTAL
CAP.
WB
MBH
CFM
°F
72
287
67
262
9400
62
257
57
257
72
280
67
259
9000
62
251
57
251
72
273
67
256
8000
62
245
57
245
72
271
-67
251
7000
62
243
57
243
72
268
67
245
6000
62
240
57
240
AIR ON
EVAPORATOR
COIL
TOTAL
CAP.
WB
MBH
CFM
°F
72
260
67
238
9400
62
233
57
233
72
254
67
235
9000
62
228
57
228
72
248
67
233
8000
62
223
57
223
72
246
67
228
7000
62
221
57
221
72
244
67
223
6000
62
218
57
219
Unitary Products Group
TEMPERATURE OF AIR ON OUTDOOR COIL
85°F
SENSIBLE CAPACITY, MBH
POWER
ENTERING DRY BULB, °F
INPUT
KW
86
83
80
77
21.3
216
188
159
131
20.7
262
238
210
182
20.3
257
257
257
229
20.3
257
257
257
229
21.2
203
177
151
125
20.6
251
227
201
175
20.2
251
251
248
222
20.3
251
251
248
222
21.2
190
166
143
119
20.5
240
216
193
169
20.1
245
245
239
215
20.2
245
245
239
215
21.0
177
156
135
114
20.4
222
201
180
159
20.0
243
239
227
205
20.0
243
239
227
205
20.8
164
146
127
109
20.2
205
186
168
149
19.8
240
232
214
195
19.8
240
232
214
195
TEMPERATURE OF AIR ON OUTDOOR COIL
105°F
SENSIBLE CAPACITY, MBH
POWER
ENTERING DRY BULB, °F
INPUT
KW
86
83
80
77
24.2
207
179
151
123
23.5
238
227
199
171
23.0
233
233
233
205
23.1
233
233
233
205
24.1
195
169
143
117
23.4
233
217
191
165
22.9
228
228
230
204
23.0
228
228
230
204
24.0
183
159
135
112
23.3
228
207
183
159
22.8
223
223
227
203
22.9
223
223
227
203
18.8
170
149
128
106
18.2
211
191
170
149
17.9
221
220
214
193
17.9
221
220
214
193
13.6
157
138
120
101
13.2
195
176
158
139
12.9
218
217
201
182
13.0
219
217
201
182
TOTAL
POWER
CAP.
INPUT
MBH
KW
74
71
68
103
-
-
274
22.7
154
126
97
250
22.0
201
173
144
245
21.6
201
173
145
245
21.6
99
-
-
267
22.6
149
123
97
248
21.9
196
170
144
240
21.5
196
170
144
240
21.5
95
-
-
261
22.5
145
121
97
245
21.8
192
168
144
234
21.4
192
168
144
234
21.5
93
-
-
259
22.3
138
117
96
240
21.6
184
163
142
232
21.2
184
163
142
232
21.3
91
-
-
256
22.1
131
112
94
235
21.4
177
158
140
230
21.0
177
158
140
230
21.0
TOTAL
POWER
CAP.
INPUT
MBH
KW
74
71
68
95
-
-
246
25.7
142
114
86
225
24.9
177
149
120
221
24.5
177
149
121
221
24.5
91
-
-
241
25.5
139
113
87
223
24.8
178
152
126
216
24.4
178
152
126
216
24.4
88
-
-
236
25.4
135
111
88
221
24.7
180
156
132
211
24.2
180
156
132
211
24.3
85
-
-
233
25.2
128
107
86
216
24.5
172
151
129
209
24.0
172
151
129
209
24.1
83
-
-
231
24.9
121
102
84
212
24.2
164
145
127
207
23.8
164
145
127
207
23.8
95°F
SENSIBLE CAPACITY, MBH
ENTERING DRY BULB, °F
86
83
80
77
74
211
183
155
127
99
250
232
204
176
148
120
245
245
245
217
189
161
245
245
245
217
189
161
199
173
147
121
95
243
222
196
170
144
118
240
240
240
214
188
162
240
240
240
214
188
162
187
163
139
116
92
236
212
188
164
141
117
234
234
234
210
186
162
234
234
234
210
186
163
174
153
132
110
89
218
197
176
154
133
112
232
230
221
200
178
157
232
230
221
200
179
157
161
142
124
105
87
200
181
163
144
126
107
230
226
208
189
171
152
230
226
208
189
171
152
115°F
SENSIBLE CAPACITY, MBH
ENTERING DRY BULB, °F
86
83
80
77
74
203
175
147
119
90
225
221
193
165
137
109
221
221
221
192
164
136
221
221
221
193
164
136
191
165
139
113
87
223
211
185
159
133
107
216
216
221
195
169
143
216
216
221
195
169
143
179
155
131
108
84
221
201
177
154
130
106
211
211
221
197
173
149
211
211
221
197
173
149
166
145
124
102
81
205
186
165
144
123
101
209
209
207
186
165
144
209
209
207
186
165
144
153
134
116
97
79
189
171
152
134
115
207
207
194
175
157
139
207
207
194
176
157
139
71
68
-
-
92
133
133
-
-
92
136
136
-
-
93
139
139
-
-
91
136
136
-
-
89
134
134
71
68
-
-
81
108
108
-
-
81
117
117
-
-
82
125
125
-
-
80
123
123
-
-
97
78
120
120