Cooling Capacities - York SUNLINE 2000 B1HN090 Manual

Single package air-to-air dual fuel heat pumps, 7-1/2 & 10 nominal tons
Table of Contents

Advertisement

COOLING CAPACITIES - 7-1/2 TON (BHN090)
Air On
Indoor
Coil
Total
Power
1
2
Cap.
Input
WB
CFM
°F
MBH
KW
72
104
7.7
67
100
7.6
3750
62
99
7.5
57
95
7.4
72
101
7.7
67
98
7.6
3375
62
96
7.5
57
93
7.4
72
98
7.6
67
97
7.5
3000
62
93
7.4
57
90
7.3
72
96
7.6
67
93
7.5
2625
62
91
7.4
57
88
7.3
72
93
7.4
67
89
7.3
2250
62
88
7.3
57
85
7.2
Air On
Indoor
Coil
Total
Power
1
2
Cap.
Input
WB
CFM
°F
MBH
KW
72
99
8.6
67
87
8.5
3750
62
83
8.4
57
83
8.3
72
95
8.6
67
85
8.4
3375
62
80
8.3
57
79
8.3
72
91
8.6
67
82
8.4
3000
62
76
8.3
57
76
8.3
72
89
8.6
67
79
8.4
2625
62
74
8.3
57
74
8.2
72
87
8.6
67
76
8.4
2250
62
73
8.3
57
72
8.2
1
These capacities are gross ratings. For net capacity, determine the KW of the supply air blower motor from the Blower Performance Table, multiply this value by 3.415 MBH / KW to determine
the motor heat, and deduct this heat from the gross capacity of the unit.
2
These ratings include the compressor and the outdoor fan motors but not the supply air blower motor.
NOMINAL RATING
Unitary Products Group
85°F
1
Sensible Capacity
, MBH
Entering Dry Bulb, °F
86
83
80
77
74
82
71
60
49
38
100
89
78
67
56
99
99
99
88
76
95
95
95
84
73
76
66
56
46
36
93
84
74
63
53
96
96
93
83
73
93
93
91
81
71
70
61
52
43
34
87
78
69
60
51
93
93
87
78
69
90
90
86
77
68
64
56
48
41
33
80
72
64
56
48
91
88
82
74
66
88
86
81
73
65
59
52
45
38
31
73
66
59
52
45
88
83
76
69
62
85
82
75
68
61
105°F
1
Sensible Capacity
Entering Dry Bulb, °F
86
83
80
77
74
80
69
58
46
35
87
84
75
63
52
83
83
83
72
60
83
83
83
71
60
73
63
53
43
33
83
79
70
60
49
80
80
79
69
59
79
79
78
68
58
66
58
49
40
31
80
73
65
56
47
76
76
76
67
58
76
76
74
65
56
61
53
45
37
29
74
67
59
51
44
74
74
71
63
55
74
74
69
61
53
56
49
42
35
28
68
61
54
47
40
73
72
65
59
52
72
71
64
57
50
Temperature of Air on Outdoor Coil
Total
Power
1
Cap.
Input
MBH
KW
71
68
-
-
108
7.9
44
33
96
7.9
65
54
87
7.8
62
50
88
7.8
-
-
104
7.9
43
33
93
7.9
63
53
84
7.8
61
50
84
7.8
-
-
99
7.9
42
33
91
7.9
60
51
81
7.8
59
50
81
7.8
-
-
97
7.9
40
32
87
7.9
58
50
79
7.8
57
49
79
7.8
-
-
95
7.9
38
31
84
7.9
55
48
77
7.8
54
47
77
7.8
Temperature of Air on Outdoor Coil
, MBH
Total
Power
1
Cap.
Input
MBH
KW
71
68
-
-
91
9.4
41
30
79
9.0
49
38
78
8.9
49
38
77
8.8
-
-
87
9.3
39
29
76
9.0
49
39
75
8.8
48
38
74
8.7
-
-
83
9.2
38
29
74
8.9
49
40
72
8.8
47
38
71
8.7
-
-
81
9.2
36
28
71
8.9
47
39
70
8.8
45
37
69
8.6
-
-
79
9.2
34
27
69
8.9
45
38
69
8.7
43
36
68
8.6
ALL SENSIBLE CAPACITY
95°F
Sensible Capacity
2
Entering Dry Bulb, °F
86
83
80
77
82
71
60
48
96
89
78
67
87
87
87
76
88
88
88
77
75
65
55
45
91
83
73
63
84
84
84
74
84
84
84
74
69
60
51
42
86
77
68
59
81
81
80
72
81
81
80
71
63
55
48
40
79
71
63
55
79
79
76
68
79
79
75
67
58
51
44
37
72
65
58
51
77
77
71
64
77
77
70
63
115°F
Sensible Capacity
2
Entering Dry Bulb, °F
86
83
80
77
78
67
56
45
79
79
72
60
78
78
78
67
77
77
77
66
71
61
51
41
76
74
66
56
75
75
74
65
74
74
73
63
64
55
47
38
74
70
61
52
72
72
71
62
71
71
68
59
59
51
43
35
69
64
56
48
70
69
66
58
69
68
63
55
53
46
40
33
65
58
51
44
69
67
60
54
68
65
58
51
511.17-TG2Y
1
, MBH
74
71
68
37
-
-
55
44
33
65
54
42
65
54
43
35
-
-
53
42
32
64
54
44
64
54
44
33
-
-
50
41
32
63
54
45
62
53
44
32
-
-
47
39
31
60
52
44
59
51
43
31
-
-
44
37
30
57
50
43
56
49
42
1
, MBH
74
71
68
33
-
-
49
38
27
56
45
34
55
44
33
31
-
-
46
36
26
55
45
35
52
42
32
29
-
-
43
35
26
53
44
35
50
41
32
27
-
-
40
32
24
50
42
34
47
39
31
26
-
-
37
30
23
47
40
33
44
37
30
5

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sunline 2000 b1hn120

Table of Contents