Manuals and User Guides for York BQ240. We have
3
York BQ240 manuals available for free PDF download: Installation Manual, Technical Manual
York BQ240 Installation Manual (40 pages)
SINGLE PACKAGE HEAT PUMP
Brand:
York
| Category:
Heat Pump
| Size: 2.12 MB
Table of Contents
Table of Contents
2
General
4
Safety Considerations
4
Inspection
4
Reference
4
Renewal Parts
4
Approvals
4
Product Nomenclature
5
Installation
6
Installation Safety Information
6
Limitations
6
Location
6
Unit Application Data
6
Rigging and Handling
7
Clearances
7
Ductwork
7
Typical Rigging
7
Center of Gravity
7
Fixed Outdoor Air Intake Damper
8
Condensate Drain
8
Fixed Outdoor Air Damper
8
Compressors
9
Filters
9
Service Access
9
Recommended Drain Piping
9
Typical Field Wiring
10
Thermostat
11
Power and Control Wiring
11
Optional Electric Heat
11
Control Wire Sizes
11
Optional Economizer/Motorized Damper
12
Rain Hood
12
Optional Power Exhaust/Barometric Relief Damper Rain Hood
12
Optional Economizer and Power Exhaust Damper Set Point Adjustments and Information
12
Minimum Position Adjustment
12
Enthalpy Set Point Adjustment
12
Power Exhaust Damper Setpoint
12
Indoor Air Quality Aq
12
Electric Heat Application Data
12
Optional Bas-Ready Economizer Power Exhaust Damper Set Point Adjustment
13
Enthalpy Setpoint Adjustment
13
Honeywell Economizer Control W7212
14
Four and Six Point Loads
14
Center of Gravity
15
Physical Data - Basic Unit
15
Operating Weights (Lbs.)
15
Voltage Limitations
16
Electrical Data -Without Powered Convenience Outlet
16
Outlet
16
Electrical Data -With Powered Convenience
17
Electric Heat Correction Factors
17
Unit Dimensions - 20 Ton
18
Unit with Rain Hood Dimensions (20 Ton)
19
Cfm, Static Pressure, and Power - Altitude and Temperature Corrections
20
Blower Performance 20 Ton Supply Air Bottom Duct Connections
22
Factor
23
Static Resistances
23
Blower Motor and Drive Data
23
Phasing
24
Checking Supply Air Cfm
24
Air Balance
25
Pressure Drop Across a Dry Indoor Coil
25
Operation
26
Sequence of Operations Overview
26
Cooling Sequence of Operation
26
Continuous Blower
26
Intermittent Blower
26
No Outdoor Air Options
26
Sensor
26
Sensors
27
Economizer with Power Exhaust
27
Motorized Outdoor Air Dampers
27
Cooling Operation Errors
27
High-Pressure Limit Switch
27
Low-Pressure Limit Switch
27
Freezestat
27
Low Ambient Cooling
28
Safety Controls
28
Compressor Protection
28
Flash Codes
28
Reset
28
Heating Sequence of Operations
28
With Electric Heat
28
Without Electric Heat
29
Heating Operation Errors
29
Temperature Limit
29
Safety Controls
30
Flash Codes
30
Reset
30
Heat Anticipator Setpoints
30
Start-Up (Cooling)
30
Prestart Check List
30
Operating Instructions
31
Post Start Check List
31
Shut down
31
Troubleshooting
31
Cooling Troubleshooting Guide
31
Unit Flash Codes
36
Unit Control Board Flash Codes
36
Unit Control Board Option Setup
37
Option Byte Setup
37
Heat Delay Setup
37
Unit Control Board
37
Maintenance Normal Maintenance
38
Filters
38
Motors
38
Blower Shaft Bearing
38
Outdoor Coil
38
Heat Delay
38
Advertisement
York BQ240 Installation Manual (36 pages)
SINGLE PACKAGE HEAT PUMP
Brand:
York
| Category:
Heat Pump
| Size: 0.61 MB
Table of Contents
Table of Contents
2
General
4
Safety Considerations
4
Inspection
4
Reference
4
Renewal Parts
4
Approvals
4
Product Nomenclature
5
Installation
7
Installation Safety Information
7
Limitations
7
Location
7
Unit Application Data
7
Rigging and Handling
8
Clearances
8
Ductwork
8
Typical Rigging
8
Center of Gravity
8
Fixed Outdoor Air Intake Damper
9
Condensate Drain
9
Fixed Outdoor Air Damper
9
Compressors
10
Filters
10
Service Access
10
Recommended Drain Piping
10
Typical Field Wiring
11
Thermostat
12
Power and Control Wiring
12
Optional Electric Heat
12
Control Wire Sizes
12
Electric Heat Application Data
12
Optional Economizer/Motorized Damper
13
Rain Hood
13
Optional Power Exhaust/Barometric Relief Damper and Rain Hood
13
Optional Economizer and Power Exhaust Damper Set Point Adjustments and Information
13
Minimum Position Adjustment
13
Enthalpy Set Point Adjustment
13
Power Exhaust Damper Setpoint (with or Without Power Exhaust)
13
Indoor Air Quality Aq
13
Enthalpy Setpoint Adjustment
14
Honeywell Economizer Control W7212
15
Four and Six Point Loads
15
Center of Gravity
16
Four and Six Point Loads
16
Physical Data - Basic Unit
17
Operating Weights (Kg./Lbs.)
17
Voltage Limitations
18
Electrical Data -Without Powered Convenience Outlet
18
Electrical Data -With Powered Convenience Outlet
18
Electric Heat Correction Factors
18
Unit Dimensions - 20 Ton
19
Detail "X" Accy. Side Supply & Return
20
Cfm, Static Pressure, and Power - Altitude and Temperature Corrections
21
Altitude Correction Factors (°C/Meter)
21
Altitude Correction Factors (°F/Feet)
21
Altitude/Temperature Conversion
22
Bq240 Supply Air with Downflow Duct
23
Applications
23
Static Resistances
24
Blower Motor and Drive Data
24
Phasing
25
Checking Supply Air Cfm
25
Air Balance
26
Pressure Drop Across a Dry Indoor Coil Vs Supply Air Cfm
26
Operation
27
Sequence of Operations Overview
27
Cooling Sequence of Operation
27
Continuous Blower
27
Intermittent Blower
27
No Outdoor Air Options
27
Economizer with Single Enthalpy
27
Sensor
27
Economizer with Dual Enthalpy Sensors
28
Economizer with Power Exhaust
28
Motorized Outdoor Air Dampers
28
Cooling Operation Errors
28
High-Pressure Limit Switch
28
Low-Pressure Limit Switch
28
Freezestat
28
Low Ambient Cooling
28
Safety Controls
29
Compressor Protection
29
Flash Codes
29
Reset
29
Heating Sequence of Operations
29
With Electric Heat
29
Without Electric Heat
29
Heating Operation Errors
30
Temperature Limit
30
Safety Controls
30
Flash Codes
31
Reset
31
Heat Anticipator Setpoints
31
Start-Up (Cooling)
31
Prestart Check List
31
Operating Instructions
31
Post Start Check List
31
Shut down
31
Troubleshooting
31
Cooling Trouble Shooting Guide
31
Unit Flash Codes
35
Maintenance
36
Normal Maintenance
36
Filters
36
Motors
36
Blower Shaft Bearing
36
Outdoor Coil
36
Unit Control Board Flash Codes
36
York BQ240 Technical Manual (32 pages)
SUNLINE 2000 SINGLE PACKAGE AIR-TO-AIR HEAT PUMPS 20 NOMINAL TONS, 8.8 EER
Brand:
York
| Category:
Heat Pump
| Size: 0.48 MB
Table of Contents
Description
1
Table of Contents
2
Product Nomenclature
3
List of Figures
5
Features
11
Factory-Installed Options
12
Field-Installed Accessories
13
Sunline 2000Tm Heat Pump
14
Ratings
14
Indoor Sound Power Ratings
14
Cooling Capacities - 20 Ton
15
Heating Capacities - 20 Ton
16
Altitude Correction Factors
17
Altitude/Temperature Conversion Factor
18
Blower Performance - 20 Ton Supply Air
19
Blower Motor and Drive Data
20
Static Resistances
20
Power Exhaust Performance
20
Electronic Thermostat Field Wiring
21
Field Wiring 24 Volt Thermostat
21
Field Wiring Disconnect
22
Voltage Limitations
22
Electrical Data -Without Powered Convenience Outlet
23
Electrical Data -With Powered Convenience Outlet
24
Electric Heat Correction Factors
24
Physical Data
25
Operating Weights (Lbs.)
25
Unit Dimensions - 20 Ton
26
Minimum Clearances
26
Utilities Entry Data
26
Detail "X" Accy. Side Supply & Return Air Openings
27
Detail "Y" Unit with Rain Hoods
27
Center of Gravity
27
Four and Six Point Loads
28
Roof Curb Dimensions - 20 Ton
29
Roof Curb Benefits
29
Unit and Curb Applications
29
Typical Applications
30
Typical Roof-Top Installation
30
Simplicity ® CONTROL WIRING DIAGRAM
31
Guide Specifications
32
Advertisement
Advertisement
Related Products
York BQ 060
York BQ 048
York BQ 036
York Affinity BHZ048
York CHAMPION B1HH024
York PREDATOR BP 090
York Predator BP078
York B1HA024A46
York B1HA018A58
York BUZ048