TABLE 3: BP072 COOLING CAPACITIES (6 TON)
RETURN AIR
GROSS
1
CAP.
WB
MBH
CFM
TEMP
°F
72
76.1
67
71.2
1800
62
66.0
57
65.4
72
78.9
67
73.8
2100
62
68.3
57
67.8
72
81.6
67
76.3
2400
62
70.7
57
70.1
72
83.3
67
77.9
2700
62
72.1
57
71.6
72
84.9
67
79.5
3000
62
73.6
57
73.0
RETURN AIR
GROSS
1
CAP.
WB
MBH
CFM
TEMP
°F
72
67.5
67
61.4
1800
62
56.3
57
55.9
72
70.8
67
64.4
2100
62
59.1
57
58.6
72
74.2
67
67.4
2400
62
61.9
57
61.4
72
74.3
67
67.6
2700
62
62.1
57
61.5
72
74.5
67
67.8
3000
62
62.2
57
61.7
1. These capacities are gross ratings. For net capacity, deduct the supply air blower motor heat, MBH = 3.415 X kW. Refer to the
appropriate blower performance table for the KW of the supply air blower motor.
2. These ratings include condenser fan motor and compressor motor power but not the supply air blower motor power.
16
85°F
GROSS SENSIBLE CAPACITY
2
INPUT
RETURN AIR DRY BULB TEMP. °F
POWER
kW
86
83
80
77
5.26
45.5 39.7 33.8 28.0 22.2
5.19
57.8 51.9 46.1 40.3 34.4 28.6 22.8
5.13
66.0 62.8 57.0 51.2 45.3 39.5 33.7
5.12
65.4 64.0 58.1 52.3 46.5 40.6 34.8
5.28
49.9 43.4 37.0 30.6 24.2
5.21
63.3 56.9 50.4 44.0 37.6 31.2 24.8
5.15
68.3 66.8 62.4 56.0 49.6 43.1 36.7
5.14
67.8 67.0 63.6 57.2 50.8 44.4 38.0
5.30
54.2 47.2 40.2 33.2 26.2
5.23
68.8 61.8 54.8 47.8 40.8 33.8 26.8
5.17
70.7 70.7 67.8 60.8 53.8 46.8 39.8
5.16
70.1 70.1 69.1 62.1 55.1 48.1 41.1
5.31
58.0 50.1 42.1 34.1 26.2
5.24
73.3 65.3 57.4 49.4 41.4 33.5 25.5
5.18
72.1 72.1 70.7 62.7 54.7 46.8 38.8
5.17
71.6 71.6 71.1 63.1 55.1 47.2 39.2
5.32
61.9 52.9 44.0 35.0 26.1
5.25
77.8 68.9 59.9 51.0 42.0 33.1 24.2
5.19
73.6 73.6 73.6 64.7 55.7 46.8 37.8
5.18
73.0 73.0 73.0 64.1 55.1 46.2 37.2
105°F
GROSS SENSIBLE CAPACITY
2
INPUT
RETURN AIR DRY BULB TEMP. °F
POWER
kW
86
83
80
77
6.47
40.8 35.7 30.6 25.5 20.3
6.38
52.1 46.9 41.8 36.7 31.5 26.4 21.3
6.33
56.3 55.4 50.3 45.1 40.0 34.9 29.7
6.31
55.9 55.0 49.9 44.8 39.6 34.5 29.4
6.51
46.1 40.1 34.0 27.9 21.9
6.41
58.5 52.6 46.5 40.4 34.4 28.3 22.2
6.36
59.1 58.7 55.9 49.8 43.7 37.7 31.6
6.34
58.6 58.2 55.4 49.4 43.3 37.3 31.2
6.55
51.4 44.4 37.4 30.4 23.4
6.45
64.8 58.2 51.2 44.2 37.2 30.2 23.2
6.40
61.9 61.9 61.5 54.5 47.5 40.5 33.5
6.38
61.4 61.4 61.0 54.0 47.0 40.0 33.0
6.56
54.7 46.8 38.8 30.8 22.8
6.47
66.3 61.0 53.0 45.1 37.1 29.1 21.2
6.42
62.1 62.1 61.9 53.9 45.9 37.9 30.0
6.40
61.5 61.5 61.3 53.4 45.4 37.4 29.5
6.58
58.0 49.1 40.2 31.2 22.3
6.49
67.8 63.9 54.9 46.0 37.0 28.1 19.1
6.44
62.2 62.2 62.2 53.3 44.3 35.4 26.5
6.42
61.7 61.7 61.7 52.8 43.8 34.9 25.9
OUTDOOR AMBIENT TEMPERATURE
1
, MBH
GROSS
1
CAP.
POWER
MBH
74
71
68
-
-
72.6
67.0
60.9
60.7
-
-
75.7
69.8
63.4
63.2
-
-
78.7
72.6
66.0
65.7
-
-
79.6
73.4
66.7
66.5
-
-
80.5
74.2
67.5
67.2
OUTDOOR AMBIENT TEMPERATURE
1
, MBH
GROSS
1
CAP.
POWER
MBH
74
71
68
-
-
62.3
55.8
51.8
51.1
-
-
66.0
59.1
54.8
54.0
-
-
69.6
62.3
57.9
57.0
-
-
69.1
61.8
57.4
56.6
-
-
68.6
61.4
57.0
56.1
036-21630-001-B-0904
95°F
GROSS SENSIBLE CAPACITY
2
INPUT
RETURN AIR DRY BULB TEMP. °F
kW
86
83
80
77
5.80
43.1 38.0 32.9 27.7 22.6
5.74
55.0 49.9 44.7 39.6 34.5 29.3 24.2
5.67
60.9 59.8 54.7 49.5 44.4 39.3 34.1
5.67
60.7 59.9 54.7 49.6 44.5 39.3 34.2
5.83
48.2 42.1 36.0 30.0 23.9
5.77
61.2 55.1 49.0 43.0 36.9 30.8 24.8
5.70
63.4 62.9 59.9 53.9 47.8 41.7 35.7
5.70
63.2 62.8 60.0 53.9 47.9 41.8 35.7
5.86
53.2 46.2 39.2 32.2 25.2
5.80
67.3 60.3 53.3 46.3 39.4 32.4 25.4
5.73
66.0 66.0 65.2 58.2 51.2 44.2 37.2
5.72
65.7 65.7 65.3 58.3 51.3 44.3 37.3
5.87
56.9 48.9 41.0 33.0 25.0
5.81
70.8 63.7 55.8 47.8 39.8 31.9 23.9
5.74
66.7 66.7 66.3 58.4 50.4 42.4 34.4
5.74
66.5 66.5 66.3 58.3 50.3 42.3 34.4
5.89
60.6 51.7 42.8 33.8 24.9
5.83
74.2 67.1 58.2 49.3 40.3 31.4 22.4
5.76
67.5 67.5 67.5 58.5 49.6 40.6 31.7
5.76
67.2 67.2 67.2 58.3 49.4 40.4 31.5
115°F
GROSS SENSIBLE CAPACITY
2
INPUT
RETURN AIR DRY BULB TEMP. °F
kW
86
83
80
77
7.14
38.6 33.4 28.3 23.2 18.0
7.02
49.2 44.0 38.9 33.8 28.6 23.5 18.4
6.98
51.8 51.0 45.9 40.7 35.6 30.5 25.3
6.95
51.1 50.2 45.0 39.9 34.8 29.6 24.5
7.19
44.1 38.0 32.0 25.9 19.8
7.06
55.7 50.0 43.9 37.9 31.8 25.7 19.7
7.03
54.8 54.4 51.8 45.7 39.7 33.6 27.5
6.99
54.0 53.6 50.9 44.8 38.8 32.7 26.6
7.23
49.6 42.6 35.6 28.6 21.6
7.11
62.3 56.0 49.0 42.0 35.0 28.0 21.0
7.07
57.9 57.9 57.8 50.8 43.8 36.8 29.8
7.04
57.0 57.0 56.7 49.7 42.7 35.7 28.7
7.25
52.5 44.6 36.6 28.6 20.7
7.13
61.8 58.3 50.3 42.3 34.4 26.4 18.4
7.09
57.4 57.4 57.4 49.4 41.4 33.5 25.5
7.06
56.6 56.6 56.4 48.5 40.5 32.5 24.6
7.27
55.4 46.5 37.6 28.6 19.7
7.15
61.4 60.6 51.6 42.7 33.7 24.8 15.8
7.11
57.0 57.0 57.0 48.1 39.1 30.2 21.2
7.08
56.1 56.1 56.1 47.2 38.3 29.3 20.4
Unitary Products Group
1
, MBH
74
71
68
-
-
-
-
-
-
-
-
-
-
1
, MBH
74
71
68
-
-
-
-
-
-
-
-
-
-

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sunline 2000Bp 072

Table of Contents