Sign In
Upload
Manuals
Brands
York Manuals
Heat Pump
Predator BP078
York Predator BP078 Manuals
Manuals and User Guides for York Predator BP078. We have
1
York Predator BP078 manual available for free PDF download: Installation Manual
York Predator BP078 Installation Manual (56 pages)
SINGLE PACKAGE HEAT PUMP HIGH EFFICIENCY
Brand:
York
| Category:
Heat Pump
| Size: 2.5 MB
Table of Contents
Table of Contents
2
General
5
Safety Considerations
5
Inspection
5
Reference
5
Renewal Parts
5
Approvals
5
Nomenclature
6
Installation
7
Installation Safety Information
7
Preceding Installation
7
Limitations
7
Unit Shipping Bracket
7
Condenser Coil Covering
7
Compressor Section
7
Location
8
Unit Voltage Limitations
8
Unit Temperature Limitations
8
Rigging and Handling
9
Unit 4 Point Load
9
Unit 6 Point Load
9
Unit Weights
9
Point Load Weight
9
Clearances
10
Unit Center of Gravity
10
Unit Dimensions
10
Unit Height
10
Unit Clearances
10
Bottom Duct Openings
11
Ductwork
12
Duct Covers
12
Rear Duct Dimensions
12
Curbs
13
Condensate Drain
14
Compressors
14
Filters
14
Thermostat Wiring
14
Power and Control Wiring
14
Control Wire Sizes
14
Power Wiring Detail
15
Field Wiring 24 Volt Thermostat
16
Electrical Data Bp078 (6-1/2 Ton) Hp W/O Pwrd Convenience Outlet
17
Electrical Data Bp078 (6-1/2 Ton) Hp with Pwrd Convenience Outlet
17
Electrical Data Bp090 (7-1/2 Ton) Hp W/O Pwrd Convenience Outlet
18
Electrical Data Bp090 (7-1/2 Ton) Hp with Pwrd Convenience Outlet
18
Electrical Data Bp102 (8-1/2 Ton) Hp W/O Pwrd Convenience Outlet
19
Electrical Data Bp102 (8-1/2 Ton) Hp with Pwrd Convenience Outlet
19
Electrical Data Bp120 (10 Ton) Hp W/O Pwrd Convenience Outlet
20
Electrical Data Bp120 (10 Ton) Hp with Pwrd Convenience Outlet
20
Electrical Data Bp150 (12-1/2 Ton) Hp W/O Pwrd Convenience Outlet
21
Electrical Data Bp150 (12-1/2 Ton) Hp W/Pwrd Convenience Outlet
21
Factory Installed Options/ Field Installed Accessories
22
Electric Heat Accessory
22
Electric Heat Option
22
Physical Data
22
Motorized Outdoor Damper
23
Economizer
23
Power Exhaust
23
Rain Hood
23
Economizer and Power Exhaust Set Point Adjustments and Information
23
Minimum Position Adjustment
23
Enthalpy Set Point Adjustment
23
Power Exhaust Damper Set Point (with or Without Power Exhaust)
23
Indoor Air Quality Aq
23
Enthalpy Set Point Chart
24
Phasing
25
Blower Rotation
25
Belt Tension
25
Blower Performance
26
Yim-C
26
Blower Performance
29
Blower Performance
30
10 Ton Optional Motor down Shot Blower Performance
30
Yim-C
30
Blower Performance
34
Performance
35
Blower Performance
36
Air Balance
37
Checking Air Quantity
37
Method One
37
Method Two
37
Dry Coil Delta P 50" Cabinet
38
Supply Air Drive Adjustment
39
Additional Static Resistance 50" Cabinet
40
Additional Static Resistance 42" Cabinet
40
Operation
41
Sequence of Operations Overview
41
Cooling Sequence of Operation
41
Continuous Blower
41
Intermittent Blower
41
No Outdoor Air Options
41
Economizer with Single Enthalpy Sensor
41
Economizer with Dual Enthalpy Sensors
42
Economizer (Single or Dual) with Power Exhaust
42
Motorized Outdoor Air Dampers
42
Cooling Operation Errors
42
High-Pressure Limit Switch
42
Low-Pressure Limit Switch
42
Freezestat
42
Low Ambient Cooling
42
Safety Controls
43
Compressor Protection
43
Flash Codes
43
Reset
43
Heating Sequence of Operation
43
Electric Heat Operation Errors
44
Temperature Limit
44
Safety Controls
44
Limit Switch (Ls)
44
Electric Heat Limit Setting 50" Cabinet
44
Electric Heat Limit Setting 42" Cabinet
44
Flash Codes
45
Reset
45
Electric Heat Anticipator Setpoints
45
Start-Up
45
Prestart Check List
45
Operating Instructions
45
Post Start Check List
45
Superheat Charging Method
45
Superheat Charging
46
Cooling Superheat 6-1/2 Ton Heat Pump
46
Cooling Superheat 7-1/2 Ton Heat Pump
47
Cooling Superheat 8-1/2 & 10 Ton Heat Pump
47
Troubleshooting
48
Predator® Flash Codes
48
Cooling Superheat 12.5 Ton Heat Pump
48
Unit Control Board
49
Unit Control Board Flash Codes
49
Yim-C
49
Cooling Troubleshooting Guide
50
Advertisement
Advertisement
Related Products
York SUNLINE 2000 BP 072
York PREDATOR BP 090
York BP 036
York BP 048
York BP 060
York BP 072
York PREDATOR BP120
York Predator BP150
York Predator BP102
York BP 240
York Categories
Air Conditioner
Heat Pump
Chiller
Furnace
Air Handlers
More York Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL