8-2-2 OPTION MODE 1

Items/
Adjustable
Data Saved
Range
P.OFF GPS
HOLD
Select whether or not to hold the UMID GPS
position information while the power is
DATA
CLEAR
turned off, thereby keeping this information
as status data holding the previous value
until the power is turned on again, which
enables a new measurement to start.
HOLD: Hold and save the data.
CLEAR Clear the data when the power is
– C U F –
SDI METADATA ON
Select whether or not to output metadata
(UMID) to the SDI (when the optional AJ-
OFF
YA902AG is attached).
– C U F –
SDI EDH
ON
Select whether or not to add an error
OFF
detection flag to the SDI output (when the
optional AJ-YA902AG is attached).
– C U F –
SAVE SW (AUD
ON
Select whether or not to forcibly disable the
audio output when the SAVE ON/OFF
OUT)
OFF
switch is set to [ON].
ON:
OFF: Enable audio output.
– C U F –
SAVE SW (LCD) ON
Select whether or not to automatically turn
off the LCD monitor when the SAVE ON/
OFF
OFF switch is set to [ON].
ON:
OFF: Do not turn off LCD monitor.
– C U F –
SAVE SW (SDI) ON
Select whether or not to automatically
disable the SDI output when the SAVE ON/
OFF
OFF switch is set to [ON].
ON:
OFF: Enable SDI output.
– C U F –
<Note>
Menu options for setting 1394 are displayed when an IEEE1394
interface board (AJ-YAD800G, optional) is attached. For more
information, see the AJ-YAD800G instruction manual.
100
Remarks
turned off, and save zero (No-Info)
from the next power-on until a new
measurement is completed.
Disable audio output.
Turn off LCD monitor.
Disable SDI output.

8-2-3 OPTION MODE 2

Items/
Adjustable
Data Saved
Range
COMPONENT
OFF
Sets the analog component output level to
Triax, 26-pin extender, or external VTR.
OUT
BETACAM
OFF: Saves power and stops output.
M2
BETACAM:
Output using ß-CAM level.
M2:
– C U F –
26PIN
OFF
Sets the recording control between the
CONTROL
BOTH
external VTR and the AJ-SPX800P when a
26-pin camera adapter (AJ-CA905G,
optional) is attached and used with an
external VTR.
OFF: Recording is performed only with the
BOTH:Recording is performed with both the
<Note>
The Tally Lamp indicates external VTR
status. Recording status of the AJ-SPX800P
can be selected in the menu option REC
– C U F –
TALLY of SYSTEM MODE.
26PIN
NORMAL
Sets the type of VTR control signal (start/
stop recording) which is output from No. 12
CONTROL
SPECIAL
of the 26-pin connector when the 26-pin
DEFAULT
camera adapter (AJ-CA905G, optional) is
attached and controls an external VTR.
NORMAL:
Recording stop "LOW", recording start
"HIGH" (for AJ-D92).
SPECIAL:
Recording stop "HIGH", recording start
– C U F –
"LOW".
The ____ in the Adjustable Range column indicates the preset
mode.
Remarks
However, when either a 26-pin
extender, external VTR or Triax is
connected, output automatically
switches to BETACAM level.
Output using M2 level.
AJ-SPX800P, and not with the
external VTR.
AJ-SPX800P, and an external VTR.