04: ECO enable/disable
05: ECO voltage range settings
18
BAT 60:
presents output frequency
is 60Hz
If converter mode is enabled, you
may choose the following output
frequency:
CF 50:
presents output frequency
is 50Hz
CF 60:
presents output frequency
is 60Hz
Parameter 3:
Enable or disable
ECO function. You may choose the
following two options:
ENA:
ECO mode enable
DIS:
ECO mode disable (Default)
Parameter 2&3:
Set the
acceptable high voltage point and
low voltage point for ECO mode by
pressing Down key or Up key.
HLS:
High loss voltage in ECO
mode in parameter 2 (the setting
range in parameter 3 is from +7V
to +24V of the nominal voltage -
Default: +12V)
LLS:
Low loss voltage in ECO mode
in parameter 2 (the setting range
in parameter 3 is from -7V to -24V
of the nominal voltage - Default:
-12V)