Troubleshooting - DeLonghi PAC WE 110 Instructions For Use Manual

Portable air conditioner
Hide thumbs Also See for PAC WE 110:
Table of Contents

Advertisement

TROUBLESHOOTING

PROBLEM
The air conditioner
does not come on
The air conditioner
works for a short time
only
The air conditioner
works, but does not
cool the room
During operation, there
is an unpleasant smell
in the room
The air conditioner
does not operate for
about three minutes
after restarting it
The symbol and
one of the following
messages
LT / HL/Cf/PF / FI
appears on the
appliance display:
CAUSE
there is no current
it is not plugged into the outlet
the internal safety device has tripped
there are bends or kinks in the air
exhaust hose
something is preventing the air from
being discharged
windows, doors and/or curtains open
there are heat sources in the room
(oven, hairdryer, etc)
the air exhaust hose is detached from
the appliance
dust filters clogged
• the technical specification of the
appliance is not adequate for the room
in which it is located.
• dust filter and (when present)
electrostatic filter clogged
the internal compressor safety device
prevents the appliance from being
restarted until three minutes have
elapsed since it was last turned off.
The appliance has a self diagnosis
system to identify a number of
malfunctions.
SOLUTION
wait
plug into the outlet
call the Service Center
position the air hose correctly, keeping
it as short and free of curves as possible
to avoid bottlenecks.
check and remove any obstacles
obstructing air discharge
close doors, windows and curtains,
bearing in mind the "TIPS FOR
CORRECT USE" given above
eliminate the heat sources
fit the air exhaust hose in the housing at
the back of the appliance (fig. 1).
clean or replace the filters as described
above
clean the filters as described above
wait. This delay is part of normal
operation.
See the SELF-DIAGNOSIS chapter.
20

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

We125We130