Advertisement

pac360U OK GB
24-04-2003
Important Information
When using electrical appliances, basic safety precautions should always be fol-
lowed, including the following:
Read all instructions.
To protect against fire, electrical shock and personal injury, do not immerse cord,
plug or appliance in water or other liquid.
Close supervision is necessary when any appliance is used by or near children.
Do not operate with a damaged cord or plug, or after the appliance malfunctions,
or has been damaged in any manner. Return the appliance to the nearest authori-
zed De' longhi service facility for examination, repair or adjustment.
The use of accessory attachments or spare parts is not recommended by the
appliance manufacturer. It may result in fire, electrical shock or personal injury.
Do not use outdoors.
Do not use the appliance for other than the intended use.
Do not place any strain on the power cord. Avoid twisting and/or tangling.
Ensure that outlet vent of exhaust hose is kept debris-clear and obstruction free.
Ensure that ventilation holes on the rear of the machine and front louvers are not
blocked.
The Pinguino should not be installed where the atmosphere could contain combusti-
ble gases.
Avoid using Pinguino in oily or sulphurous atmospheres or near sources of heat.
Wait at least 3 minutes before restarting, after the airconditioner has been switched
off or the thermostat setting changed.
Before moving the airconditioner, remove tank and empty water from collectiong
tray (see instructions for drainage at page 14).
Do not place hot or heavy objects on the appliance.
Clean air filter every week (see instructions at page 14).
Important: If you need to use an extension cord, please be sure to use a heavy duty
extension cord (minimum 14 gauge).
2
16:32
Pagina 2
SAVE THESE INSTRUCTIONS

Advertisement

Table of Contents
loading

Summary of Contents for DeLonghi PAC 360

  • Page 1 pac360U OK GB 24-04-2003 16:32 Important Information When using electrical appliances, basic safety precautions should always be fol- • lowed, including the following: Read all instructions. • To protect against fire, electrical shock and personal injury, do not immerse cord, •...
  • Page 2 pac360U OK GB 24-04-2003 16:32 Pagina 3 Dear user, We thank you for purchasing Pinguino airconditioner and congratulate you on your wise choice. For optimal results please read this manual carefully before installing or operating. We know that the Pinguino will keep your environment pleasingly comfortable at all times.
  • Page 3: Specifications

    pac360U OK GB 24-04-2003 16:32 Power supply voltage Frequency Cooling capacity: With water Current consumption Water tank capacity Room thermostat Dimensions: width height depth Net weight Refrigerant system Compressor protection Freon charge OPTIMUM OPERATING RANGE ROOM TEMPERATURE ROOM HUMIDITY FACTOR FREQUENCY POWER SUPPLY...
  • Page 4: Description Of Main Features

    pac360U OK GB 24-04-2003 16:32 Pagina 5 Description of main features Air outlet grille Control panel Programmer (timer) Water container Castors Castor stops Water collecting tray Water container compartment door Air filter Air intake grid Exhaust hose compartment Power cord compartment Manual reset button Handle Drainage tube...
  • Page 5: Accessory Check

    pac360U OK GB 24-04-2003 16:32 Illustrated accessory list ACCESSORY CHECK Check that all parts listed in Table are included. Pagina 6 DESCRIPTION Exhaust hose Permanent wall vent Caster stop Descaling fluid Window nozzle Window bracket + door bracket Suction disc Electrostatic filter SUPPLIED...
  • Page 6: Permanent Installation

    pac360U OK GB 24-04-2003 16:32 Permanent installation PERMANENT INSTALLATION Our air-conditioner is portable and versatile: it can be used for a permanent installation or easily moved from one room to another. In case of permanent installation, air discharged from rear hose has been extracted from the room where the appliance is installed.
  • Page 7: Preparing The Unit For Use

    Insert the nozzle of the exhaust hose into the slot, then con- nect the hose to the air conditioner (Fig. 7). With the wing nut, it’s possi- ble to use the window bracket also for sliding windows.
  • Page 8 pac360U OK GB 24-04-2003 16:32 Pinguino is equipped with an adjustable win- dow bracket ( 18) . If you have a sliding win- dow, place the bracket on the window sill, extend the bracket fully within the window frame and lower the window onto the brack- et.
  • Page 9: Special Note

    OK GB 24-04-2003 16:32 In order to obtain maximum performance from your air conditioner make sure that: Doors and windows of room to be air con- ditioned are closed (with the exception of temporary installation where a partially opened window is necessary).
  • Page 10: Non-Programmed Mode

    OK GB 24-04-2003 16:32 Description of Pinguino DESCRIPTION OF PINGUINO PAC 360 CONTROLS “Alarm” pilot light Timer SETTING THE TIMER The programmer/timer, like all clocks, must be set to the exact time. If for example it is 4.00 p.m., turn the dial in a clockwise direction...
  • Page 11: Air Conditioning

    OK GB 24-04-2003 16:32 How to start up the air conditioner (see control panel on the previous page) Select the “programmed” or “non pro- Pagina 12 Plug the appliance into the wall outlet. grammed” mode (see previous page) Select the fan speed required pres- sing “Fan speed”...
  • Page 12: Maintenance

    pac360U OK GB 24-04-2003 16:32 fig. 18 During cleaning and normal maintenance ope- rations remember to disconnect plug. CLEANING OF EXTERNAL HOUSING fig.20 Clean with a damp cloth and dry thorou- ghly with a clean dry cloth. BEGINNING THE SEASON Carefully follow installa- tion procedure.
  • Page 13: Air Filter Cleaning

    pac360U OK GB 24-04-2003 16:32 Maintenance of air filter A clogged air filter reduces the quantity of cir- culating air and the efficiency of the applian- ce. Clean filter every week using a vacuum cleaner. Remove dust with a Rinse with running vacuum cleaner water fig.
  • Page 14: Periodic Maintenance

    Refill the tank with clean water and replace in the machine. Plug in and turn on the machine. While the air conditioner is operating, unplug the drainage tube and drain until the water looks clean. Replace the drainage tube plug.
  • Page 15: Limited Warranty

    We do not authorize any other person or company to assume for us any liability in connection with the sale or use of our AIR CONDITIONER. This warranty shall not apply to assume for us any liability in connection with the sale or use of our AIR CON- DITIONER.