4.3.2

Monitor setting

To output a monitored result as an analog output, set the values shown below in Pr.525 (terminal DA2),
Pr.527 (terminal DA3), Pr.529 (terminal DA4), or Pr.531 (terminal DA5). For details about the monitored
items selected with the setting values "1 to 53", refer to the description of Pr.54 FM/CA terminal function
selection and Pr.158 AM terminal function selection in the Instruction Manual of the inverter.
Setting
Types of Monitor
1
Output frequency
*1
2
Output current
3
Output voltage
5
Frequency setting value
6
Running speed
*1
7
Motor torque
*3
8
Converter output voltage
9
Regenerative brake duty
Electric thermal relay function load
10
factor
11
Output current peak value
12
Converter output voltage peak value
13
Input power
14
Output power
17
Load meter
*3
18
Motor excitation current
21
Reference voltage output
HIGH-SPEED ANALOG OUTPUT
Increments
0.01Hz
Pr.55
0.01A/0.1A
Pr.56
*2
0.1V
400V/800V
0.01Hz
Pr.55
The value converted with the Pr. 37 value from
1(r/min)
Pr. 55.
0.1%
Pr.866
0.1V
400V/800V
0.1%
Pr.70
0.1%
100%
0.01A/0.1A
Pr.56
*2
0.1V
400V/800V
Rated inverter power × 2
0.01kW/0.1kW
*2
Rated inverter power × 2
0.01kW/0.1kW
*2
0.1%
Pr.866
0.01A/0.1A
Pr.56
*2
Full Scale Value
4
17