1.4 Specifications

(1) Output signals
High-speed analog output (across the terminal 5's and the terminals DA2 to DA5), 0VDC to ±10VDC
(12-bit output resolution)
Digital output (across the terminal 5's and the terminals DD0 to DD3), 3V to 6V for HI, 0V to 2V for LOW
(2) Output accuracy (reference value)
±10% of the full-scale output value.
Depends on the output signal type.
(3) Meters used
DC voltmeter
Full-scale ±10V (internal impedance 10kΩ or more)
Wiring length
Maximum 30m