Comtech EF Data CSAT-5060 Installation And Operation Manual page 135

C-band satellite transceivers
Table of Contents

Advertisement

C-Band Transceiver
Remote Control
Arguments
for
Command
Command
or
(Instruction
Parameter
Response
Code and
Type
to Query
qualifier)
Concise
N/A
10 bytes,
Utility Status
alpha
numerical
Concise
N/A
80 bytes,
Maintenance
numerical
Status
Description of arguments
Note that all arguments are ASCII
numeric codes between 48 and 57.
Query only.
Used to Query the Utility status of the CSAT
Example: CUS=brrru.ud.d'cr''lf'
where:
b = baud rate, 1 = 1200, 2 = 2400,
3 = 4800, 4 = 9600, and 5 = 19200
rrr = reference adjust
u.u = Up converter slope adjust
d.d = Down converter slope adjust
Query only.
Used to Query the Maintenance status of the CSAT
Example: CMS=aaa.abbb.bccc.cddd.deee.e
fff.fggg.ghhh.hiii.ijjj.jkkk.klll.lmmm.m
nnn.nooo.oppp.p'cr''lf'
where:
aaa.a = 24V Power Supply
bbb.b = 20V Power Supply
ccc.c = 12V Power Supply
ddd.d = 10V Power Supply
eee.e = +5V Power Supply
fff.f = -5V Power Supply
ggg.g = TX Synthesizer Tuning Voltage
hhh.h = TX IFLO Tuning Voltage
iii.i = RX Synthesizer Tuning Voltage
jjj.j = RX IFLO Tuning Voltage
kkk.k = Reference Tuning Voltage
lll.l = LNA Current in milliamps
mmm.m = Fan Current in milliamps
nnn.n = Up Conv Heat Sink Temperature
ooo.o = RF Output Power in dB
ppp.p = Down Converter Temperature
Note: Value is xxx.x if not available
Response to
Command
(Slave to Master)
N/A
N/A
6-19
MN/CSAT5060.IOM
Query
(Instruction
Response to query
code and
(Slave to Master)
qualifier)
CUS?
CUS=x....x (see description for
details of arguments)
CMS?
CMS=x....x (see description for
details of arguments)
Revision 1

Advertisement

Table of Contents
loading

Table of Contents