CSAT-5060 C-Band Transciever
+10 dBm Model C-Band Transceiver
Common
Conversion
Dual, No Spectral Inversion
Sense
Positive, No Inversion
Frequency
1 and 2.5 MHz automatic
Step Size
± 1 x 10
Frequency
-7
Stability
1 x 10
/day
± 1 x 10
-40 to 55°C (-40 to 131°F)
Attentuation
TX
Steps
TX (Optional)
RX
RX (Optional)
Phase Noise
100 Hz
1 kHz
10 kHz
100 kHz
Group Delay
Linear
Parabolic
Ripple
M&C Methods
Both EIA-485 and EIA-232 Serial Interface
Handheld controller, optional
External
5 or 10 MHz EXT REF port available in
Reference
addition to internal frequency reference.
Connector
Redundant
Outdoor unit (ODU) with autoswitch on
Switch
failure
M&C Interface
M&C Interfaces between:
Transceivers and Switch
Switch and CMA compler
MTBF:
≥ 50,000 hours
Transceiver
≥ 90,000 hours
Switch
CE Mark
Meets CE Mark spec
-9
/day (maximum)
-8
/day (maximum)
0 to 25 dB, in 0.25 dB steps
0 to 30 dB, in 0.25 dB steps
0 to 20 dB, in 0.25 dB steps
0 to 30 dB, in 0.25 dB steps
-66 dBc/Hz
-76 dBc/Hz
-86 dBc/Hz
-96 dBc/Hz
0.1 ns/MHz
2
0.02 ns/MHz
1 ns/p-p
Environmental
Temperature:
Operating
Non-Operating
Attitude
Humidity
Rainfall
Solar Radiation
Prime Power
9–4
Revision 1
MN/CSAT5060.IOM
-40 to +55°C (-40 to 131°F)
-50 to +75°C (-58 to 167°F)
15,000 Feet,
mean sea level
0 to 100 %, Relative
50 mm/hr
350 BTU/foot2/hour
90 to 260 VAC Standard
47 to 63 Hz Standard
48 VDC Optional