Chapter 2 Configuration
Parameter
Schedule
Current Profile
Profiles
Edit Profiles
Schedule
Edit Schedule
Schedule
• To set to automatic profile switching mode, SNTP must be enabled. If SNTP is enabled but the time
cannot be obtained from the server, the profile is not automatically switched and the management
profile that was set in the schedule is applied, based on the internal clock of the switch.
• The settings in "Port PoE Settings" are saved to the profile selected in Current Profile. However, the
"Port PoE Settings" cannot be changed when in automatic profile switching mode.
• When editing the profile, set the scheduler to Manual. The profile cannot be edited when the
scheduler is set to Automatic.
Meaning
Manual:
The profile is switched manually.
Automatic:
The profile is switched automatically.
In manual profile switching mode, this indicates the profile that is
currently being used.
This displays a list of the profiles that are currently set.
Click to edit the profile information.
Click to open the profile information editing screen.
This displays a list of the schedules that are currently set.
Click to edit the schedule.
Click to open the timetable editing screen.
Weekly:
This displays the schedule by the day of the week.
Daily:
This displays the schedule by the day.