6-1-3 Setting the IP Address for the Incoming Mail Server
Set the IP address for the incomimg mail server to connect to at the [Incoming Mail Server (POP3)] field.
These settings are only required when communicating by mail with dedicated software in a remote location.
(These settings are not required when only transmitting error information by mail.)
Note: These settings are supported only for G-50A version 2.60 and above.

6-1-4 Setting the Mail Receipt Interval

Set the mail receipt interval from 1 to 60 minutes at the mail receipt interval settings field. Normally, 1 minute is
set, however, a longer interval should be set if there are cases when the mail server becomes congested.
These settings are only required when communicating by e-mail with dedicated software in a remote location.
(These settings are not required when only transmitting error information by e-mail.)
Note 1: These settings are supported only for G-50A version 2.60 and above.
Note 2: In order to increase the mail communication speed, after receiving
the latest mail, mail is checked at the mail server 6 times at 1/6th of the
time interval specified at this item.

6-1-5 Setting the User ID and Password

Set the user ID and password used for receiving mail at the [User ID] and [Password] fields. Set in the account
provided by the Internet Provider or the LAN administrator.
These settings are only required when communicating by e-mail with dedicated software in a remote location.
(These settings are not required when only transmitting error information by e-mail.)
Note:
These settings are supported only for G-50A version 2.60 and above.

6-1-6 Setting the Mail Addresses of Mail Recipients

Set the mail addresses of mail recipients in the [Mail Communication Setting] field.
These settings are only required when communicating by e-mail with dedicated software in a remote location.
(These settings are not required when only transmitting error information by e-mail.)
Note 1: These settings are supported only for G-50A version 2.60 and above.
Note 2: Mail communication is only possible with the recipient specified here.