Sony SRW-1 Operation Manual page 92

Hd portable digital recorder/hd video processor/optical interface unit/picture cache board
Hide thumbs Also See for SRW-1:
Table of Contents

Advertisement

Problem
• Picture break-up.
• "AUDIO PLL UNLOCK"
appears.
• Unnatural movement
(ghosting).
• "PB FREQ MISMATCH"
appears.
Movement stops, or is
jerky.
• Playback picture break-
up.
• "PB FMT MISMATCH"
appears.
Want to show a test signal. This can be done with menu
Test signal does not
appear.
Select FPS recording does
not work.
When joined to the HDC-
F950, Slow Shutter
recording does not operate
normally.
a) At the same time, one of the following messages may appear.
"NO PB RF", "BAD CH CONDITION", "AUDIO PLL UNLOCK", "PD
PLL UNLOCK", "NO HD REF", "NO SD REF", "HD&SD REF
ASYNC", "REF SEL NOT GOOD", "BAD HD REF", "BAD SD REF",
"INVALID SDI DATA", "SDI A-B PHASE NG", "SDI FMT
MISMATCH", "SDI I/P MISMATCH", "NO EXT SDI INPUT"
92
Troubleshooting
Cause
The input signals are unstable.
The monitor does not support the
format.
The input signal does not agree with
the system frequency.
The frequency exceeds the monitor
scanning frequency.
For 4:2:2 50P or 4:2:2 59.94P input,
"422×2" is selected for SYSTEM
>FORMAT >SIGNAL.
Wrong interlace and PsF selection.
Monitor is not operating properly.
The recorded format (PB) does not
match the playback format (SYS).
settings.
Test signals are turned off when the
unit is powered off and on.
The HKSR-102 board is not
installed.
The camera does not support the
Select FPS function.
The SRW-1 software does not
support the Select FPS function.
The Select FPS function is not
enabled on either the camera or the
VTR.
The LFE function of the HDC-F950
is operating incorrectly.
Steps to take
Input the correct signals.
Some older monitors support only the 59.94/60
frequencies. Some of the newest monitors support the 720-
50P format. Use a monitor with specifications supporting
the format.
Input a signal with 1.000/1.000 and 1.000/1.001 that agree
with the system.
If the monitor is a BVM-F24, 25PsF and 29.97PsF cannot
be displayed with ×3 scanning, resulting in picture break-
up. Use ×2 or ×1 scanning. For 59.94i and 50i, use ASD
scanning.
Select "422". "422×2" should be selected for DUAL
STREAM during 3D shooting, etc.
Set the input signal format so as to match the system signal
format.
Check the monitor settings. Try turning it off and on again.
Put the display at the bottom right of the HOME screen into
format display mode, and set the matched SYS and PB
formats.
Select CB or BLK under SYSTEM >TEST SG >VIDEO.
Select the test signal again.
Install the optional HKSR-102 board to use the Select FPS
function.
Select a camera that supports the Select FPS function
before setting SELECT FPS to ON.
Upgrade to a version that supports the Select FPS function.
(Contact a Sony service representative.)
Enable the Select FPS function on both the camera and the
VTR.
Every time changing the settings of LFE or stored frames
on the HDC-F950, be sure to power off and on the camera,
open the iris, and record bright images for testing. Then,
start actual recording.