Input Voltage Changeover - 230/460 Voltage Units Only; Input Air Connection / Fuse Replacement; Section 3 - ESAB PowerCut 1300 Instruction Manual

Manual & mechanized plasmarc cutting package
Hide thumbs Also See for PowerCut 1300:
Table of Contents

Advertisement

SECTION 3

3.5.1 INPUT VOLTAgE CHANgEOVEr - 230/460 VOLTAgE UNITS ONLY

208 - 230 or 460 Mode
To simplify the use of the PowerCut 1300/1600 with different input voltages, it has been equipped with a 230/460
voltage selector switch located on the rear panel of the unit. Switching between 230 and 460 voltages can be
done by using a flathead screwdriver. You will hear two clicks when switching between 230 and 460 positions.
Do not allow switch to remain in the center position. This switch should never be changed when machine power
is on. Damage could result.
Input Voltage
Selector Switch
Pre-filtered DRY AIR SUPPLY (Customer Supplied)
(90 - 150 psi / 6.2 - 10.3 bars)
3.5.2 INPUT AIr CONNECTION
Connect your air supply to the inlet connection of the filter.
figure 3-2. Input Connections / fuse replacement
Replace fuse with Slo-Blo, 2 Amp, 600 V only
WArNINg
MAKE SUrE THE POWEr
SOUrCE IS SWITCHED Off
BEfOrE rEMOVINg fUSE.
48
INSTALLATION

Hide quick links:

Advertisement

Table of Contents
loading