Clearances; Mantel Clearances - Travis Industries 616 Diamond-Fyre GSR2 Owner's Manual

Fireplace insert with screen
Hide thumbs Also See for 616 Diamond-Fyre GSR2:
Table of Contents

Advertisement

10
Installation (for qualified installers only)

Clearances

Due to the high temperature of the heater, it should be located out of traffic and away from furniture and draperies.
S ide
k
Wall
l

Mantel Clearances

The maximum mantel depth is 12" (305mm).
NOTE: The combustible area above the facing must not protrude more than 3/4" (20mm) from the facing.
If it does, it is considered a mantel and must meet the mantel requirements listed in this manual.
Above Base of Insert (n)
© Travis Industries
n
m
p
x
37"+(940mm+)
36"(915mm)
35"(889mm)
Mantel Height
34"(864mm)
33"(839mm)
32"(813mm)
31"(788mm)
k Sidewall to Insert
l Side Facing
(non-combustible)
m Top Facing*
(non-combustible)
n 12" Mantel* (combustible
or non-combustible)
n 4" Mantel* (combustible
or non-combustible)
p Hearth Extension to the
Front
x Extension onto Hearth
* Measured from the base of the insert.
NOTE: The non-combustible top facing must
extend 35.5" (902mm) above the base of the
insert or to the bottom of the mantel (whichever
is less).
Maximum Mantel Depth
4140811
Minimum
Clearances
6"
153mm
5"
127mm
35.5"
902mm
36.5"
928mm
33"
839mm
12"
305mm
0"
0mm
100-01331