Optional Bottom Cover Installation; Owner's Information - Valor Retrofire RF24IDN Installation And Owner's Manual

Direct vent fireplace insert
Hide thumbs Also See for Retrofire RF24IDN:
Table of Contents

Advertisement

Important: When the bottom cover is used instead of a fret,
a space is required in front of the window to allow the window
to move and relieve during a hard start. It is therefore very
important to ensure that an area of 3/4 inch (19 mm) in front
of the window is kept clear at all times.
Hook the upper fl ange of the bottom
cover onto the window bolts.
Rear View
Top
Bottom
CAUTION
Your fi replace becomes very hot when operating.
Your fi replace becomes very hot when operating.
Avoid placing decorating objects sensitive to heat
Avoid placing decorating objects sensitive to heat
within 36 inches (0.9 m) around it.
within 36 inches (0.9 m) around it.
Performance of LPG appliances may be affected by
the quality of commercial gas supplied in your area.
Warranty
Card at the
back of this
manual.
Please read the
Safety and Warning
Information section at
the beginning of this
manual.
Operating Your Fire
For your safety, this appliance is fi tted with a fl ame
supervision device which will shut-off the gas supply
if, for any reason, the pilot fl ame goes out. This device
incorporates a fi xed probe, which senses the heat
from the pilot fl ame. If the probe is cool, the device will
prevent any gas fl ow unless the burner control knob is
kept pushed in at the PILOT position. See full lighting
instructions on page 25 of this manual.
Cleaning
WARNING
DO NOT TOUCH THE GLASS WHILE IT IS HOT!
DO NOT TOUCH THE GLASS WHILE IT IS HOT!
Let the fi replace cool fi rst before cleaning it.
Let the fi replace cool fi rst before cleaning it.
It will be necessary to clean the glass periodically.

Optional Bottom Cover Installation

Top flange
Side View
Front
Bottom flange
(bends here)

Owner's Information

Fireplace
Hearth
Do not put
furniture or other objects
in this space in front of
the fireplace:
36" (0.9 m)
An area of 3/4 inch (19 mm) in front of the
window MUST be kept clear at all times!
DO NOT use
this hole
Top
Rear
Bottom
(end plates longer
than front plate
at bottom)
During startup, condensation, which is normal, forms
on the inside of the glass and causes dust, lint etc. to
cling to the glass surface. Initially paint, while curing,
may deposit a slight fi lm on the glass. We therefore
recommend that, during the fi rst few weeks of use,
the glass be cleaned two or three times with non-
abrasive common household cleaners and warm
water. Ammonia based cleaners should not be used.
Subsequently, the glass should be cleaned two or three
times a season depending on the circumstances.
Do not clean the glass while it is hot.
Always securely replace the window before lighting.
If broken, the glass pane may only be replaced
as a complete window unit as supplied by the
manufacturer.
It is necessary to remove the cast iron fret and
brackets or the bottom cover before removing the
window—see previous installation sections.
The window
can be removed
for cleaning by
rotating the two
fastening studs at
the bottom corners
90 degrees to
release, and
swinging the
bottom of the
window unit
outwards to
unhook the top edge.
After refi tting the window, apply light hand pressure against
the window frame sides to bed-in the window seal.
Hook the top
flange of the
bottom cover
to the window
retaining pins
Check that Window
Moves Freely After
Reinstallation
Spring Loaded
Fastening Studs (2)
1/4 Turn
19