Operation Check And Aeration Adjustment; Optional Cast Iron Fret Installation - Valor Retrofire RF24IDN Installation And Owner's Manual

Direct vent fireplace insert
Hide thumbs Also See for Retrofire RF24IDN:
Table of Contents

Advertisement

Turn the fi replace up and down using the remote control to confi rm
that the full range of inputs is achieved.
Light the fi re and allow to warm up for 10–15 minutes to evaluate
the fl ame picture.
The burner is equipped with an adjustable air
shutter to control primary aeration. See fi gures below. The shutter is
factory-set at an aeration gap, which will give optimum performance
for the vast majority of installations. In a few unusual installations,
fl ame picture may be improved by adjusting the aeration. The need
for adjustment should be determined only by operating the appliance
with the ceramic fuel effects and window installed.
Increasing aeration will cause the fl ame to appear more
transparent and blue making the ceramic fuel effects
glow more.
Decreasing aeration will cause the fl ames to appear
more yellow or orange making the fuel effects glow less.
Too little aeration may result in black carbon
forming and dropping into the fi rebox.
Important: The fret retainer brackets are designed to
maintain the required space in front of the window to
allow the window to move and relieve during a hard
start. It is very important to ensure this area in front
of the window is kept clear at all times.
Fret Retainer Brackets Installation
Screw 2 thumbscrews into sides of each support
leg if not done previously when support legs were
installed. Fit the slotted holes in the fret retainers over
the thumbscrews, push fret retainers downwards and
tighten screws.
Cast Iron Fret Installation
Adjust screw heads on back of fret to the thickness of
the retainer bracket and drop the fret into place while
guiding the screw heads into the slots in the bracket.
Clip the ash pan cover onto the fret.
18

Operation Check and Aeration Adjustment

Optional Cast Iron Fret Installation

Air Shutter Components
Air Shutter in
Open Position
Air Shutter
Air Shutter Retainer
Air Shutter in
Closed Position
Slip fret retainer
over thumbscrews
and tighten screws
Drop fret with bolt into
slotted retainer (fret
adjusts up or down to suit)