Hearth Protection; Clearances - Jøtul GI 350 DV Scan 65i Installation And Operation Instructions Manual

Direct vent gas fireplace insert
Hide thumbs Also See for GI 350 DV Scan 65i:
Table of Contents

Advertisement

Clearance to Combustible
Materials
A combustible material is anything that can
burn (i.e. sheet rock, wallpaper, wood, fabrics etc.).
These surfaces are not limited to those that are vis-
ible and also include materials that may be behind
non-combustibles.
If you are unsure of the combustible nature of a
material, consult your local fire officials. "Fire Resis-
tant" materials are considered combustible: they are
difficult to ignite, but will burn. "Fire-rated" sheet
rock is also considered combustible.
The following clearances and hearth specifications
are the minimum requirements for installation into
a masonry or factory built fireplace. Mantel and wall
clearances will vary, depending upon the fireplace
facing and riser height, if needed. Use the tables and
illustrations in figs. 4 and 5 to determine the mini-
mum clearances for your installation.
Hearth Requirements
Hearth protection in front of the GI 350 DV must be
composed of any noncombustible material. It must
extend 16" forward of the firebox glass panel and
extend 18" to either side of the fireplace centerline.
See fig. 4.
Figure 4. Hearth, Trim and Wall clearances.

Fireplace Facing Options
Jøtul Cast Iron Surround - 34 1/2" x 24 1/2"
w/ Plinth - 34 1/2" x 26 1/2"
w/Wide Surround Panel - 38" x 26"
w Plinth Extensions - 38 1/2" x 28"
Steel Door Kits - includes Surround panels
38" Wide x 28" High
SCAN i Surround Assembly
- with 1" Riser: 40" Wide x 27" High
- with 2" Riser: 40" Wide x 28" High
Surround
A
b
Type
Jøtul
18"
16"
Cast Iron
Jøtul
Cast Iron
18"
16"
w/ plinth
Steel
Double
18"
16"
Doors
Scan i
w/ Mantel
18"
16"
Heat Shield
Scan i
without
18"
16"
Mantel
Heat Shield
Table 1. Hearth, Trim and Wall clearances.
A: Hearth Protection Width - 18" from centerline.
B: Hearth Protection Depth - 16"
C: Side Trim Clearance, 1 1/2" thick. Shown measured
from fireplace centerline = 1" from Cast Iron and 0"
(zero clearance) from Steel Surround.
D: Side Room Wall Clearance shown measured from
the fireplace centerline = 24" from Surround.
E: Top Trim Clearance = Same as 3.5" deep mantel.
See fig. 5.
C
D
E
18 1/4"
41 1/4"
35"
18 1/4"
20"
41 1/4"
37"
w/ Wide
Surround
19"
43"
38"
37": 1"
Riser
21"
44"
38": 2"
Riser
Use
Use
noncom-
noncom-
44"
bustible
bustible
materials
materials
only.
only.