Prefabricated Fireplaces - Jøtul GI 350 DV Scan 65i Installation And Operation Instructions Manual

Direct vent gas fireplace insert
Hide thumbs Also See for GI 350 DV Scan 65i:
Table of Contents

Advertisement

Exhaust
Listed, Standard
or High-Wind
Termination Cap
Sealed Chimney
Cap Anchor Plate
Listed Flexible
Gas Liners
Max. Height 35 ft.
Min. Height 10 ft.
In the U.S., the Air
Intake pipe must
extend through the
damper and into
the first chimney
flue.
Maintain proper
clearance to Mantel
and Trim.
See pages 8-9.
Metal block-off plate
is required to seal flue
from the living area
if Air Intake pipe does
not connect directly to
a Direct Vent Termina-
tion at the top of the
chimney
Attach Fireplace Conversion
Notice Plate to Rear Wall of
fireplace if the damper has
been modified or removed.
Figure 6. Masonry Fireplace Venting Configuration.
Air intake must connect to chimney cap in Canada.
WARNING:
FAILURE TO pOSITION THE pARTS IN ACCOR-
DANCE WITH THIS DIAGRAM OR FAILURE TO USE
ONLY pARTS SpECIFICALLY AppROVED WITH THIS
AppLIANCE MAY RESULT IN pROpERTY DAMAGE
OR pERSONAL INJURY.
prefabricated (Factory-built)
Fireplaces
Air
Intake
This appliance may be installed into a prefabricated
fireplace listed per UL 127 or ULC S610.The chimney
must be clean and in good working order. It must be
constructed of noncombustible materials. Chimney
clean-outs must fit properly.
A factory-built prefabricated fireplace may require
modifications before installation of the fireplace
insert.
Modification Steps:
1. Remove any fuel grate or other components at-
tached to the firebox. On most models the fire
grate is attached to the unit with brackets which
should be cut or pried off.
2. Remove the damper assembly. This includes the
damper blade, handle and any linkage.
Two 3" liners must be able to pass through the
damper area.
3. Remove any fire screen or door assembly. This is
usually done by removing a support rod on the
inside of the fireplace frame. Smoke shelves,
shields, and baffles can be removed if attached
with mechanical fasteners.
4. If there is a metal ash lip, it too should be re-
moved to allow the unit to sit flat in the fireplace.
Be sure to reinstall any screws removed.
• Do not cut or remove permanent steel
components of the prefabricated fireplace.
If the fireplace has no gas access hole(s)
provided, an access hole, 1.5" diameter or
less, may be drilled through the lower side
or bottom of the firebox in a proper, work-
man-like manner. The hole must be sealed
with non-combustible insulation after the
gas supply line has been installed.
• Do not remove air channel walls.
• Do not block buil-in air passageways.
THE USE OF AN EXISTING CHIMNEY AS AN AIR
INTAKE IS NOT COVERED UNDER THE ANSI
Z21.88-1999-CSA 2.33-M99 TEST METHODS AND
RESULTING ITS/WHI PRODUCT CERTIFICATION.
THE CODE AUTHORITY HAVING JURISDICTION
MUST BE CONSULTED PRIOR TO PROCEEDING
WITH THIS INSTALLATION METHOD.