Advertisement

Jøtul C 350
Winterport
Fireplace Insert
Installation and Operating Instructions
for the United States & Canada
Keep these instructions for future reference.
1

Advertisement

Table of Contents
loading

Summary of Contents for Jøtul C 350

  • Page 1 Jøtul C 350 Winterport Fireplace Insert Installation and Operating Instructions for the United States & Canada Keep these instructions for future reference.
  • Page 3: Table Of Contents

    Specifications The serial number and manufacturing date are C 350 Winterport Fireplace Insert ......6 located on the permanent label on the back of the firebox. You may also wish to attach your sales receipt to this manual for future reference.
  • Page 4: Standards And Safety Notices Standards / Codes

    Tested to U.S. Standards: ANSI/UL 1482, Canadian Standards: CAN/ULC-S627-M93 Standards Check Building Codes The Jøtul C 350 Fireplace Insert has been tested and When installing, operating and maintaining your listed to: U.S: ANSI/UL 1482 Jøtul C 350 Fireplace Insert, follow the guidelines...
  • Page 5: Safety Notices

    EMIC S OR FL dealer install your new Jøtul C 350 Fireplace Insert. S S S S S T T T T T AR ART T T T T T T T T T H H H H H E FI E FI E FIR R R R R E.
  • Page 6: Specifications

    Performance Fuel: 20” Logs Heat Output 40,000 BTU/hr. (4.1 kg/hr.) The Jøtul C 350 Winterport Fireplace Insert meets U.S. Heating Capacity : Up to 1,300 sq. ft. EPA emission limits for wood heaters sold after July Overall Efficiency : 71% 1990, and is tested and listed to ANSI/UL 1482, and CAN/ULC S628.93.
  • Page 7: Installation

    Masonry Fireplace Requirements Factory-Built Fireplace Requirements • The entire fireplace and chimney must be cleaned The Jøtul C 350 Winterport may be installed into a and inspected before installation. The system must factory-built fireplace with the following conditions: meet local building code requirements.
  • Page 8: Hearth Protection

    Hearth Protection Requirements The floor area in front of fireplace insert must be Min. protected from live sparks and radiant heat. 16” from door opening • • • • • Ma Materials: terials: terials: terials: terials: Hearth protection must be non- combustible insulating board, or the equiva- Combustible lent mortared masonry material.
  • Page 9: Clearance To Combustibles

    Mantel Clearances Clearance to Combustible Materials Clearance reduction to mantel construction may be • There may be no combustible materials located made in conformance to NFPA 211 or CAN/CSA B365. anywhere within 36” (914 mm) of the front of the fireplace insert.
  • Page 10: Chimney Connection

    Chimney Connection This insert must be connected to a code-approved A 6”, 7”, or 8” stainless steel liner, extending the masonry chimney or listed factory-built fireplace full height of the chimney, is required for all installa- chimney with a direct (positive) flue connector into tions where the flue tile is greater than 8”...
  • Page 11 Installation 1. 1. 1. 1. 1. Remove the existing damper and linkage compo- nents from the fireplace. Alternatively, you can wire the damper plate to lock it in the open position. Thoroughly clean the firebox and smokeshelf area with a wire brush. 2.
  • Page 12: Firebox Installation

    Install the Riser Bar 1. If appropriate to your installation (see pg. 8), center the Riser Bar within the masonry fireplace as shown in fig. 9. The forward ends of the Riser Bar should be aligned within 1/2 inch of the fireplace face.
  • Page 13: Surround Assembly

    Bracket Plate Left Bottom Trim Right Bottom Trim Figure 13. Bottom Surround Trim assembly. C 350 Surround Assembly Tighten just snug enough to allow for final adjustment when the Surround assembly is attached to the firebox. All f All f...
  • Page 14: Operation

    •Cardboard •Colored paper Use the following guide to establish optimal perfor- •Solvents •Any synthetic fuel or logs mance from the C 350. The burning of any of these materials can result in Burn R Burn R Burn R Burn R...
  • Page 15: Starting / Maintaining The Fire

    Creosote Formation 1” in diameter) on top of the newspaper, with two to three small logs (approx. 2” to 3” in diameter) The Jøtul C 350 WINTERPORT is designed to burn on top. wood cleanly and efficiently when operated as 3.
  • Page 16: Blower

    PLUGGED DIRECTLY INTO A PROPERLY GROUNDED THREE- PRONG RECEPTACLE. DO NOT CUT OR REMOVE THE GROUNDING SWITCH PRONG FROM THE PLUG. MANUAL OFF AUTO ALWAYS DISCONNECT THE POWER SUPPLY WHEN Figure 16. C 350 Wiring diagram. PERFORMING ANY SERVICE ON THE FIREPLACE INSERT.
  • Page 17: Maintenance

    EPT T T T T A A A A A C C C C C LE. ECEP SPECIFICALLY DESIGNED FOR THE The container of ashes should be placed on a JØTUL C 350 WINTERPORT FIREPLACE INSERT. DO NOT USE noncombustible floor or on the ground, well away SUBSTITUTES. REPLACEMENT...
  • Page 18: General Maintenance

    General Maintenance Gask Gask Gaskets Gask Gask Regular maintenance will assure proper perfor- Check door and glass gaskets for seal integrity. mance and prolong the life of your Jøtul C350. The The gaskets should be soft enough to be somewhat following procedures do not take long and are resilient to the touch.
  • Page 20 Figure 19. Jøtul C 350 Illustrated Parts Diagram...
  • Page 21: Parts List

    126244 Jøtul C 35 Jøtul C 35 Jøtul C 35 Jøtul C 35 Jøtul C 350 0 0 0 0 W W W W W in in in in interpor terpor terpor terport t t t t Options terpor Options...
  • Page 22: Miscellaneous Replacement Parts

    Cast Iron Assembly Replacement Parts Description Description Description Description Description P P P P P ar ar ar ar artNumber tNumber tNumber tNumber tNumber Front Door Assembly, Complete inc. castings, handle and gaskets Matte Black Paint 156066 Blue Black Enamel 156067 Jøtul Iron Paint 156068...
  • Page 24 This appliance must be installed in conformance with local and national building regulations. It is important that the these instructions be carefully read and understood before beginning the installation. Jøtul pursues a policy of continual product development. Consequently, products may differ in specification, color or type of accessories from those illustrated or described in various publications.

Table of Contents