Variable Length Format
SET ------------------------------------------
Enable Variable Length
Format
Set Minimum Label
Length
END ------------------------------------------
SR60 Scanner Programmer's Reference Manual
Chapter 4 — Enabling and Configuring Symbologies
Note: To set a label length less than ten, you must scan a zero
digit first and then the length digit (such as 04, 06, or 08).
6 Scan the END bar code.
---------
---------

Fixed Length Format

The scanner offers the option of requiring Codabar labels to have
one or two fixed lengths in the Fixed Label Format.
To set Codabar symbology to Fixed Length Format
1 Identify the fixed length settings you want to make.
2 Scan the SET bar code on page 96.
3 Scan the Enable Fixed Length Format bar code.
4 Scan the Set First Fixed Length bar code.
5 Using the Digits bar codes on page 97, scan the digits to set
the first fixed label length you identified in Step 1.