CONNECTION TO THE GAS SUPPLY

The gas connection must be made in compliance with the local regulations in force.
Be careful when flexible pipes are used that they do not come into contact with
moving parts.
To maintain the thickness of 3 cm, the hob is fitted with a channel to contain the
connection pipe.
The gas inlet union can be turned in the direction required after the union C (figures
15a and 15b) and nipple A connection has been slackened with two spanners (Fig.
16).
Never put it in the horizontal or vertical position.
IMPORTANT:
Never attempt to turn the elbow "C" without having first slackened off
the relative lock nipple "A".
The seal "F" and the biconical gasket "B" (fig. 15a - 15b) guarantees the
seal of the gas connection.
It is recommended that they be replaced whenever they show even the
slightest deformation or imperfection.
After connecting to the mains, check that the couplings are correctly
sealed, using soapy solution, but never a naked flame.
The connection with rigid metal pipes should not cause stresses to the
hob base.
Figure 16
15