CONTENTS LED Status Microcontroller Power State Reset Proper Placement of Charging Station Storage
E nvironment
Operating
E nvironment
Single Unit Charger Technical
S pecifications
Box
...
LED STATUS The Linea-pro 5 charging stations use a bi-color LED to indicate the charging cycle state. LED Charging Status No Device in Cradle Device Charging Charging Complete 2
USER MANUAL ...
MICROCONTROLLER POWER STATE RESET An integrated microcontroller measures the current and temperature. Each charging bay has its own microcontroller and is managed independently from other charging bays. When the current or temperature states are detected at or higher than maximum levels, the power is reset until acceptable levels are achieved.
PROPER PLACEMENT OF CHARGING STATION 1. Place in an open and well-ventilated area (i.e. not a drawer or cabinet). 2. Power supplies should not be placed on top of each other. 3. The charger should be placed on a flat surface. 4.
SINGLE UNIT CHARGER TECHNICAL SPECIFICATIONS Features Parameters Double LEDs for Charging Status Red LED–Charging; Green LED–Ready/No Device Temperature: 0 – 40°C Humidity: 35 – 85% Operating Environment Temperature: -5 – 40°C Humidity: 10 – 90% Storage Environment 5V mini USB A to B type or Power Supply AC/DC Adapter 5V/1A Dimensions (LxWxH) mm...
FEDERAL COMMNICATIONS COMMISION This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation.