Low Battery Indication
Remote handset: BATT will appear on the display when
the battery needs to be replaced.
Replace with one 9 V alkaline battery.
Receiver: Three short 'beeps' will sound when the motor
turns when the batteries need to be replaced. Replace with four 1.5 V alkaline batteries.
NOTE: With very low battery, the valve shuts off the fi re completely. This does not happen when the power supply is
interrupted.
Handset / Receiver Match
The remote control handset and receiver are programmed to function together. In case of a replacement of the handset
or the receiver, you will need to reset the receiver to allow them to function together. Contact your dealer for details
Automatic Standby Mode
If there is no transmission from the handset to the receiver within a 6-hour period, the appliance will go to Standby
(pilot) mode.
Required Kits
Liners (choose one)
618EBL—Enamel Black Liner (Steel)
620FBL—Fluted Black Liner (Ceramic)
621VRL—Valor Red Brick Liner (Ceramic)
622LSL—Ledgestone Liner (Ceramic)
Surrounds (choose one)
660LSV—Landscape Surround Vintage Iron
662SSV—Square Surround Vintage Iron
Inner Bezel (choose one—required with Surround)
661BSB—Inner Bezel Black
661BSN—Inner Bezel Nickel
661BSC—Inner Bezel Copper
661BSP—Inner Bezel Polished
Optional Kits
619RSK—Rock Set Kit, to convert fuel bed from logs to
rocks.
34
34
Remote Control Operation
DO NOT USE a screwdriver or other metallic object
to remove the batteries from the battery box or the
handset! This could cause a short circuit.

Options

755CFK—Circulating Fan Kit
Having variable speed and temperature control, it
is designed to boost the natural convection process
through the appliance. It may be fi tted before the
fi replace is installed or retrofi tted at a later date
provided power is available.
NOTE: The power supply to the fan should be
controlled by a wall switch to allow convenient ON/OFF
control of the fan.
650NGK—Natural Gas Conversion Kit
For conversion from propane to natural gas. Intended
primarily for post installation conversion in areas where
natural gas was not available at the time of initial
installation.
650PGK—Propane Gas Conversion Kit
For conversion from natural gas to propane gas.
Hearth Gate (optional)
Hearth gates such as Kidco's are available at retail
stores carrying safety products for children.