4.000kΩ
0.001kΩ
40.00kΩ
0.01kΩ
400.0kΩ
0.1kΩ
4.000MΩ
0.001 MΩ
40.00 MΩ
0.01 MΩ
Capacitance Measurement
Range
Frequency
50.00nF
0.01nF
500.0nF
5.000µF
0.001µF
50.00µF
0.01µF
100µF
Frequency Count Accuracy
Function
Range
50.00Hz
500.0Hz
Frequency
5.000KHz
50.00KHz
100.0 KHz
Duty cycle ratio
0.1%~99%
TC Measurement
Function
Input Range
K
-200 to 950
RTD Measurement
Function
Input Range
Pt100
-200 to 700
Diode Test
Range
Frequency
1.000V
0.001V
Continuity Check
Range
Frequency
400.0Ω
0.1Ω
0.2%+4
0.2%+4
0.2%+4
0.5%+4
1%+4
Accuracy
4%+5
0.1nF
2%+5
2%+5
2%+5
1µF
4%+5
Resolution
0.01Hz
0.1Hz
1Hz
0.01KHz
0.1KHz
0.1%
Resolution
0.5%+2(≤-100 )
1
0.5%+1(> -100 )
Resolution
1
Accuracy
10%
Accuracy
Beeps if the value is less than 50Ω 130μA(typical value)
www.tmatlantic.com
To improve the accuracy of the low capacitance
value, open the circuit, and then press
automatically subtract the capacitance of the meter
and the leads.
Accuracy
0.1%+3
0.1%+3
0.1%+3
Display updates 3 times/second (at
0.1%+3
>10Hz)
0.1%+3
1%
Accuracy
By using ITS-90 temperature scale
Note: The accuracy does not include the
Accuracy
By using Pt100-385 temperature scale
0.5%+2
Measuring current 1mA
Note: attached lead resistance is excluded
Short Circuit current
Less than 0.2mA
(typical value)
Short Circuit current
- 28 -
Remark
Remark
Remark
error
of
internal
compensation caused by a sensor.
The range of the internal temperature
compensation sensor is + 2 .
Remark
Open Circuit voltage
1.1V to1.6V
Open Circuit voltage
< 0.45V
to
temperature