www.tmatlantic.com Ⅲ. Safety Note In accordance with IEC1010 clause (the safety standard issued by International Electrotechnical Commission), IT is designed and produced according to the safety requirements of pollution level Ⅱ. Warning: In order to avoid endangering the operator’s safety, prior to the operation of the instrument, please read the instruction manual carefully, and conform to the safety warning information and operation instruction strictly to use the instrument.
www.tmatlantic.com Ⅳ. Description of Safety Symbols Warning! Battery Undervoltage High Voltage! Danger! AC/DC In accordance with the instructions of European Ground Trade Union Double Insulation Fuse Ⅴ. Description of Instrument Panel and Pushbutton Functions 1. Instrument model. 2. LCD display area. 3.
www.tmatlantic.com Input Port: Measure the positive input terminal of voltage, frequency, resistance, capacitance, diode as well as on-and-off test, and insert red meter pen. 7. 10A current input jack: Measure the positive input terminal of 10A shift AC/DC current, and insert red meter pen. 8.
www.tmatlantic.com polarity of the red meter pen wire and the tested voltage value are spontaneously displayed on the display. Caution: a)Voltages over DC1000V or AC750V cannot be tested. b) When measuring high voltages, special precautions must be taken to avoid electrical shock.When measurement is completed, immediately disconnect the meter pen and the measured circuit.
www.tmatlantic.com X. DC Current (DCA) 1. Press the “ “ button or “ “ button. Plug the black meter pen into the terminal of “COM” and the red meter pen nto the terminal of “mA” or “10A”. See the picture below. 2.
www.tmatlantic.com Overload protection: 0.6A/250V fuse; 10A/250V fuse. Frequency response: 40-400Hz. Duty Cycle Display: (0.1%-99.9%). XII. Resistance 1. Press “ “ button, and respectively plug the red and black meter pens into the holes of “ ”and “COM”. switch 2.Circularly press “ “...
www.tmatlantic.com Measurement Range Display value condition Forward DC current Diode forward is about 1.0mA, and voltage drop backward voltage is about 3.0V. diode If Buzzer emits a switch buzzer long sound and the switch Open circuit voltage resistance of the is about 1.2V points measured as 30Ω...
www.tmatlantic.com 2. Connect the instrument to computer by USB cable. See the picture on the right: 3. Press “RS232/REL” over 2 seconds and the “RS232/REL” symbol will be displayed on screen. 4. Once the testing data is transmitted to computer,you could start recording, analyzing, processing and printing the data. For more details, please kindly refer to instructions in the software.