13. Standard voltage (at delivery)
Connected load
Fuse rating
Min. cross-sectional area of supply lead
Connection cable length (H05(07)RN-F) without
plug
Voltage
Connected load
Fuse rating
Min. cross-sectional area of supply lead
Connection cable length (H05(07)RN-F) without
plug
Voltage
Connected load
Fuse rating
Min. cross-sectional area of supply lead
Connection cable length (H05(07)RN-F) without
plug
It is recommended to make electrical connection via a
plug and socket so that electrical safety checks can be
carried out easily. The socket must be accessible after
machine installation.
With a fixed installation, this must be via a main switch to
be provided on site, which must totally isolate the machine
from the mains with a contact gap of at least 3 mm.
The fitting of an earth leakage circuit breaker is strongly
recommended.
If necessary, an equipotential bond with good contact
connection must be provided in accordance with all
appropriate national and local regulations.
Max. temperature
Max. water hardness
Min. flow pressure
Min. flow pressure with extended water intake
Max. pressure
Flow rate
On-site threaded union
Connection hose length (supplied)
Machine is DVGW certified. Direct connection to mains water
supply without special safety stopcock permitted.
Water connection Australia:
To prevent back-syphonage, the water connection must be
via an approved Dual-Check-Valve supplied with the
machine.
Max. temperature
Max. water hardness
Min. flow pressure
Min. flow pressure with extended water intake
Max. pressure
Flow rate
On-site threaded union
Connection hose length (supplied)
Machine is DVGW certified. Direct connection to mains water
supply without special safety stopcock permitted.
Water connection Australia:
To prevent back-syphonage, the water connection must be
via an approved Dual-Check-Valve supplied with the
machine.
V/Hz
3 AC 220/60
kW
6.7
A
3 × 20
mm²
5 × 2.5
m
2.3
V/Hz
3N AC 380/60
kW
6.7
A
3 × 16
mm²
5 × 2.5
m
2.3
V/Hz
AC 220/60
kW
4.7
A
1 × 25
mm²
3 × 4
m
2.1
°C
20
°dH
60
kPa
250
kPa
100
kPa
1000
l/min
8
inch
¾ male thread
(USA: 11.5 NH)
mm
1500
°C
70
°dH
60
kPa
250
kPa
100
kPa
1000
l/min
8
inch
¾ male thread
(USA: 11.5 NH)
mm
1500