4.
ADJUSTMENT
This chapter explains the adjustment necessary when replacing a part. Adjustment is made by
changing a parameter value set in EEPROM on the controller PCB. A parameter is able to set
with the key operation on the operator panel. This printer has three kinds of the maintenance
mode, it is required to select one of the maintenance mode necessary when replacing a part.
4.1
Maintenance Modes And Functions
•
User maintenance mode
To enter the user maintenance mode, turn on the POWER switch while pressing the MENU
key.
[Function]
There are 14 functions as follows.
•
Menu reset
•
Hex dump
•
Drum counter reset
•
Resource Save
•
Receive Buffer Size
•
ECP mode Enable/Disable in the parallel interface
•
Operator panel menu disable
•
X adjust
•
System maintenance mode
Note: This mode is used only by service persons and it should not be released to the end-
To enter the system maintenance mode, turn on the POWER switch while pressing the
RECOVER key.
[Function]
There are 9 functions as follows.
•
Page count display
•
Page count printing enable/disable
•
Rolling ASCII continus prinitng
•
RS232C LOOP TEST
•
EEPROM reset
•
HSP ERROR recovery
•
HSP ERROR count display
•
HSP ERROR count reset
•
SIDM enable/disable
40931201TH Rev. 4
users.
•
Y adjust
•
Duplex adjust
•
Select paper source command parameter
(Second, Third, Front Tray)
•
Page placement
•
Setting
•
Cleaning cycle
90 /