10.2 Communication Transaction Examples

10.2.1 Transaction A Example

Host requests 9 bytes of data beginning at hexadecimal memory address 1000
address 03:
1. Host sends interrogate message:
01111110 11100011 00001001 00000000 00010000 11111100
SOH
Command NUM
+ I.A.
2. AW400 sends response message:
01111110 00100011 00001001 00000000 00010000 XXXX XXXX XXXX LRC
SOH
Command NUM
+ I.A.

10.2.2 Transaction B Example

Host sends two bytes of new data, to be loaded into the AW400 at data-link address 03 beginning at
hexadecimal memory address 1000
1. Host sends change message:
01111110 10100011 00000010 00000000 00010000 00001000 00001100 11001001
SOH
Command NUM
+ I.A.
2. AW400 sends response message:
01111110 00100011 00000010 00000000 00010000 00001000 00001100 01001001
SOH
Command NUM
+ I.A.
3. Host sends acknowledge message:
01111110 10000011
SOH
Command
+ I.A.
4. AW400 performs the change requested at end of the current program scan.
Note: Database address table is shown at the end of this section.
LO ADD
HI ADD
LO ADD
HI ADD
:
H
LO ADD
HI ADD
Data 1
LO ADD
HI ADD
Data 1
from the AW400 at data-link
H
LRC
Data 1 ...........Data 9
Data 2
LRC
Data 2
LRC