11 APPENDICES

11.1 EC Declaration

AW400 line (T17M*4000A) fulfils the compliance to the mandatory tests specified by the applicable harmonised generic rules to
apply the CE Mark, according to European Directive 89/336/EEC and subsequent modifications.
As the final environment may be industrial or residential, the test were performed according to the worst case test set (industrial test
for immunity, residential test for emission). For CE Mark, owing to both the residential and industrial environment applications, the
reference rules are the following "Generic Standards":
CENELEC EN 50081-1/1992 (CEI 110-7) Electromagnetic compatibility - Generic emission standard - Part 1: residential,
commercial and light industry
CENELEC EN 50082-1/1992 (CEI 110-8) Electromagnetic compatibility - Generic immunity standard - Part 1: residential,
commercial and light industry
CENELEC EN 50081-2/1993 (CEI 110-13) Electromagnetic compatibility - Generic emission standard - Part 2: industrial
environment
CENELEC EN 50082-2/1995 (CEI 110-25) Electromagnetic compatibility - Generic immunity standard - Part 2: industrial
environment
TEST
DESCRIPTION
EN 55022
Conducted emission
EN 55022
Radiated emission
EN 61000-4-4
Electromagnetic compatibility - Part 4: Testing
and measurement techniques - Section 4:
Electrical fast transient/burst immunity test
EN 61000-4-5
Electromagnetic compatibility -Part 4:
Testing and measurement techniques -
Section 5: Surge immunity test
EN 61000-4-6
Electromagnetic compatibility - Part 4: Testing
and measurement techniques -
Section 6: Conducted disturbances induced by
radio frequency fields immunity test
EN 61000-4-11
Voltage fluctuations
EN 61000-4-11
Electromagnetic compatibility - Part 4: Testing and
measurement techniques - Section 11: Voltage dips,
short interruptions and voltage variations immunity test
EN 61000-4-3
Electromagnetic compatibility - Part 4:
Testing and measurement techniques -
Section 3: Radiated, radio-frequency
electromagnetic field immunity test
EN 61000-4-2
Electromagnetic compatibility - Part 4:
Testing and measurement techniques -
Section 2: Electrostatic discharge immunity test
EN 61000-4-8
Electromagnetic compatibility - Part 4: Testing
and measurement techniques - Section 8: Power
frequency magnetic field immunity test
AW400 line (T17M*4000B) also fulfils the compliance to the EN61010-1 rules.
EC Declaration
LEVELS
Class B
Class B
CM=2kVp on power cable;
CM=2kVp on I/O analog/digital cable;
CM=1kVp on serial cable
CM=4kVp, DM=2kVp on power cable
CM=2kVp, DM=1kVp on I/O analog/digital
cable
CM=10Vrms+mod.AM 1kHz
Range 150kHz-230MHz
Vn 10%
-100% for 5 s
-30% for 10 ms
-60% for 100 ms
10Vrms/m + mod. AM 1kHz
AD=8kVp, CD=4kVp
30A/m
65