Golden Blount EL GRANDE HD5030-TV Installation And Operating Instructions Manual

Top-vent fireplace
Hide thumbs Also See for EL GRANDE HD5030-TV:

Advertisement

INSTALLER/CONSUMER RETAIN THIS APPLIANCE
MANUAL WITH THE INSTALLED APPLIANCE

INSTALLATION AND OPERATING INSTRUCTIONS

MODEL HD5030-TV TOP-VENT FIREPLACE
IMPORTANT! Read all instructions carefully before starting
installation. Failure to follow these instructions may result in
property damage, personal injury or possible loss of life.
WARNING: If the information in these
instructions is not followed exactly, a
fire or explosion may result causing
property damage, personal injury or
death.
– Do not store or use gasoline or other
flammable vapors and liquids in the
vicinity of this or any other appliance.
– WHAT TO DO IF YOU SMELL GAS:
• Do not try to light any appliance.
• Do not touch any electrical switch;
do not use any phone in your
building.
• Immediately call your gas supplier
from a neighbor's phone. Follow the
gas supplier's instructions.
• If you cannot reach your gas
supplier, call the fire department.
– Installation and service must be
performed by a qualified installer,
service agency or the gas supplier.
MANUFACTURED BY:
4301 WESTGROVE DRIVE
ADDISON, TX 75001
GOLDEN BLOUNT
EL GRANDE
CSA APPROVED FOR NATURAL GAS OR PROPANE GAS
The Flue Damper must be in the full
open position when burning the gas
logs.
This fireplace is to be burned only with
the gas log set supplied with the
fireplace. Burning other items could
cause a fire hazard or injury.
For best results, Natural Gas pressure
should be 7" to 12" W.C. and 11" W.C.
for Propane Gas.
To simulate real wood burning, the gas
burner is designed to burn a yellow
flame. It is normal for the logs to soot-
up. The soot can be easily removed
with a vacuum cleaner or soft brush.
Check the label on the firebox to
assure the proper gas type. Never
use anything but the correct gas type
for your fireplace.
This appliance complies with National
Safety and is tested and listed to ANSI
Z21.50A - 1998 as Vented Gas fireplaces.
Installation must conform to local codes.
In the absence of local codes, installation
must conform with the current National
Fuel Gas Code, ANSI Z223.1.
Massachusetts State Code requires
damper to be welded open or removed.
9/05

Advertisement

Table of Contents
loading

Summary of Contents for Golden Blount EL GRANDE HD5030-TV

  • Page 1: Installation And Operating Instructions

    INSTALLER/CONSUMER RETAIN THIS APPLIANCE MANUAL WITH THE INSTALLED APPLIANCE INSTALLATION AND OPERATING INSTRUCTIONS GOLDEN BLOUNT EL GRANDE MODEL HD5030-TV TOP-VENT FIREPLACE CSA APPROVED FOR NATURAL GAS OR PROPANE GAS IMPORTANT! Read all instructions carefully before starting installation. Failure to follow these instructions may result in property damage, personal injury or possible loss of life.
  • Page 2: Table Of Contents

    TABLE OF CONTENTS Section Layout Options ........................ 2 Identification of Parts ....................... 3 Building Codes and Safety Standards ................4 Piping and Gas Pressure Requirements ................. 5 Installation Instructions ....................6 Log Placement ......................11 Operating Guidelines ....................13 Lighting Instructions ...................... 15 Trouble Shooting ......................
  • Page 3: Identification Of Parts

    HD5030-TV TOP-VENT FIREPLACE Outside Air Port Gas Line Access INTERIOR VIEW Damper Control Lever Pilot Light Valve Access Pan Burner Panel On/Off Switch Outside Air Outside Air Control Knob Control Knob...
  • Page 4: Building Codes And Safety Standards

    BUILDING CODES AND SAFETY STANDARDS The design of this FIREPLACE has been tested and is listed with CSA INTERNATIONAL in accordance with THE AMERICAN NATIONAL STANDARDS INSTITUTE - ANSI Z21.50. Latest Edition, CSA Test Report No. 188842-1684324. This manual serves only as a basic guideline for installation and use of this firebox and gas piping.
  • Page 5: Piping And Gas Pressure Requirements

    GAS PIPING AND GAS PRESSURE REQUIREMENTS NOTE: THIS FIREPLACE HAS A HIGH BTU INPUT. GAS PIPING SIZE AND DISTANCES SHOULD BE APPROPRIATE FOR 100,000 BTU/HR INPUT. All gas piping must be installed to comply with local codes, or, in the absence of local codes, with the latest edition of the National Fuel Gas Code ANSI Z223.1.
  • Page 6: Installation Instructions

    INSTALLATION INSTRUCTIONS In planning the installation for the fireplace, it is necessary to determine where the unit is to be installed, the routing of the B-type vent system, and whether optional accessories are to be used. Gas supply piping should also be planned. Model HD5030-TV (with the use of the Outside Air Kit) can be installed in a bedroom (in the United States) which has a total volume of unconfined space appropriate to the particular installation.
  • Page 7 10' Rule of Thumb indicates a shorter chimney height. Note: Installations which will not allow the 10' rule to be followed must be submitted to Golden Blount Inc. for approval. 1-800-833-1139.
  • Page 8 Installing Outside Air Kit Model HD5030-TV is supplied with the component parts for outside combustion with the exception of the 4" flex duct. It is recommended that the outside air system be used whenever possible. Connect 4" Class-1 Flex duct or Metal Vent to duct collar on both sides of firebox; run ducts to fresh air source and terminate using duct termination caps.
  • Page 9 REFRACTORY PANEL INSTALLATION The Refractory Brick Panels should be carefully removed from shipping sleeve and positioned upright against a stable object. 1. Look into fireplace opening and locate back panel retaining clip positioned against rear wall of fireplace. (Figure 9.1) Remove (2) screws attaching clip to rear wall and set clip and screws aside.
  • Page 10 Gas Log Installation 1. Fill burner pan with silica sand supplied with fireplace. Note! On L.P. models vermiculite is used instead of silica sand. Be careful not to pour vermiculite over brass air mixer attached to burner pan. Air mixer holes must not be obstructed! 2.
  • Page 11: Log Placement

    LOG PLACEMENT FOR MODEL# HD5030-TV LOG SET STEP 1 STEP 2 STEP 3 STEP 4 STEP 5 STEP 6...
  • Page 12 STEP 7 STEP 8 FINAL ARRANGEMENT...
  • Page 13: Operating Guidelines

    OPTIONAL GLASS DOOR INSTALLATION 1. INSTALL GB DOOR TRACKS AND HINGE SPRINGS AS ILLUS- TRATED IN (FIGURE 13.1) USING 6 SCREWS IN FIREPLACE CHASIS. 2. SCREW HANDLES ON TO DOORS. DOOR TRACK (TOP) 3. INSTALL DOORS AS SHOWN IN (FIGURE 13.2). HINGE SPRING NOTE! BRIDGE...
  • Page 14 OPERATING GUIDELINES (CONT’D) When lit for the first time, the appliance will emit a slight odor for an hour or two. This is due to paint and lubricants used in the manufacturing process. The main burner flame characteristics are steady, not lifting or floating.
  • Page 15: Lighting Instructions

    FOR YOUR SAFETY READ BEFORE LIGHTING WARNING: IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE. C. Use only your hand to push in or turn the gas A.
  • Page 16 TO TURN OFF GAS TO APPLIANCE TO TURN OFF GAS TO APPLIANCE 1. Open valve access door panel 2. Turn knob clockwise to pilot position then depress and continue turning to “OFF” 3. Close access door panel LPG (PROPANE) WARNING THE FOLLOWING WARNING APPLIES TO INSTALLATIONS USING L.P.
  • Page 17: Trouble Shooting

    TROUBLE SHOOTING With proper installation and maintenance, your new Gas Fireplace should provide years of trouble-free service. If you do experience a problem, refer to the trouble shooting guide shown below. This guide will assist a qualified service person in the diagnosis of problems and the corrective action to be taken.
  • Page 18 TROUBLE SHOOTING (CONT’D) SYMPTOM POSSIBLE CAUSE CORRECTIVE ACTION 2. Pilot will not stay lit A. Defective pilot 1. Check pilot, flame must after carefully following generator impinge on pilot generator. lighting instructions. Clean and or adjust pilot for maximum flame impingement on generator.
  • Page 19 TROUBLE SHOOTING (CONT’D) SYMPTOM POSSIBLE CAUSE CORRECTIVE ACTION 3. Pilot burning, no A. Damper control lever in 1. Set damper control lever gas burner, valve knob closed position to open position. “ON”, “ON/OFF” switch “ON”. B. “ON/OFF” switch or 1. Check ON/OFF switch wires defective and wires for proper connections.
  • Page 20: Replacement Parts

    REPLACEMENT PARTS THE FOLLOWING REPLACEMENT PARTS ARE AVAILABLE FROM YOUR GOLDEN BLOUNT DEALER ITEM PART # DESCRIPTION ITEM PART # DESCRIPTION HD-101 Gas Valve - N/G HD-118 Step 2 Log HD-102 Gas Valve - LP HD-119 Step 3 Log HD-103 1/4"...
  • Page 21 OPERATING INSTRUCTIONS, GOLDEN BLOUNT WILL TAKE THE FOLLOWING ACTIONS: 1. WITHIN THE FIRST YEAR FROM THE DATE OF INSTALLATION, GOLDEN BLOUNT SHALL, AT ITS OPTION REPLACE OR REPAIR ANY SUCH DEFECT IN MATERIAL OR WORKMANSHIP, AT GOLDEN BLOUNT’S EXPENSE, INCLUDING A REASONABLE LABOR ALLOWANCE AS DETER- MINED BY GOLDEN BLOUNT.