IMPORTANT! Read all instructions carefully before starting
installation. Failure to follow these instructions may result in
property damage, personal injury or possible loss of life.
WARNING: If the information in these
instructions is not followed exactly, a
fire or explosion may result causing
property damage, personal injury or
death.
f i r e - p a r t s . c o m
– Do not store or use gasoline or other
flammable vapors and liquids in the
vicinity of this or any other appliance.
– WHAT TO DO IF YOU SMELL
GAS:
• Do not try to light any appliance.
• Do not touch any electrical switch;
do not use any phone in your
building.
• Immediately call your gas supplier
from a neighbor's phone. Follow the
gas supplier's instructions.
• If you cannot reach your gas
supplier, call the fire department.
– Installation and service must be
performed by a qualified installer,
service agency or the gas supplier.
MANUFACTURED BY:
4301 WESTGROVE DRIVE
ADDISON TX. 75001
GOLDEN BLOUNT
SUPER-FIRE
PFS APPROVED FOR NATURAL GAS OR PROPANE GAS
■ The Flue Damper must be in the
full open position when burning the
gas logs.
■ This fireplace is to be burned only
with the gas log set supplied with the
fireplace. Burning other items could
cause a fire hazard or injury.
■ For best results, Natural Gas pressure
should be 7" to 12" W.C. and 11" W.C.
for Propane Gas.
■ To simulate real wood burning, the gas
burner is designed to burn a yellow
flame. It is normal for the logs to soot
up. The soot can be easily removed
with a vacuum cleaner or soft brush.
■ Check the label on the firebox to
assure the proper gas type. Never
use anything but the correct gas type
for your fireplace.
This appliance complies with National
Safety and is tested and listed to ANSI
Z21.50 - 2014 as Vented Gas fireplaces.
Installation must conform to local codes.
In the absence of local codes, installation
must conform with the current National
Fuel Gas Code, ANSI Z223.1.
6/16 REV

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SF4224-TV and is the answer not in the manual?

Questions and answers

Summarization of Contents

General Safety and Gas Leak Procedures
Key Safety Warnings
Covers critical safety precautions, fire hazards, and steps to take if gas is detected.
Component Identification
Exterior and Interior Views
Identifies key external and internal components of the fireplace through labeled diagrams.
Building Codes and Safety Standards
Appliance Specifications and Clearances
Details appliance type, venting, control system, and required installation clearances.
Gas Piping and Pressure Requirements
Gas Supply, Pressure, and Safety
Outlines gas piping standards, required pressures for NG/LP, regulator needs, and leak detection safety.
Installation Instructions
Planning, Placement, and Framing
Covers planning, unit placement options, mounting surfaces, and framing requirements.
Chimney and Vent System Installation
Framing Dimensions and Vent Height Rules
Provides minimum framing dimensions and guidelines for determining chimney height for proper draft.
Installation Procedures
Outside Air Kit, Gas Line, and Log Setup
Guides on installing the outside air kit, connecting gas, finishing walls, and placing logs.
Component Installation
Refractory Panels and Diverters
Details the installation process for refractory brick panels and the downdraft diverter.
Exhaust Diverter Installation
Securing the Exhaust Diverter
Instructions on how to attach the exhaust diverter within the fireplace.
Log Placement Guide
Arranging Logs on the Grate
Step-by-step visual guide for correctly arranging the fireplace logs on the grate for optimal appearance.
Millivolt Model Operation
Startup, Flame, and Maintenance
Details startup, expected flame characteristics, and essential maintenance checks.
Lighting Procedures and Safety
Pre-Ignition Safety and Gas Leak Checks
Emphasizes crucial safety checks, gas leak procedures, and safe control handling before lighting.
Step-by-Step Pilot Ignition
Provides a detailed, step-by-step guide for successfully lighting the pilot light.
Gas Shut-off and LP Precautions
Turning Off Gas and LP Safety
Explains how to turn off the gas and provides critical safety warnings specific to LP (propane) gas usage.
Troubleshooting (Millivolt Models)
Ignition and Gas Supply Issues
Covers common ignition failures and pilot light issues, listing causes and corrective actions.
Millivolt Troubleshooting Continued
Pilot Not Staying Lit and Circuitry
Addresses issues with the pilot light staying lit and potential problems with pilot circuitry or the valve.
Millivolt Troubleshooting Part 3
Burner Operation and High Limit Switch
Diagnoses issues related to the main burner not firing and pilot flame stability problems.
STP Model Operation
Spark Ignition Startup and Maintenance
Details startup for Spark-to-Pilot models, including flame characteristics and maintenance.
STP Model Wiring and Safety
STP Wiring Diagram and Safety Checks
Presents the wiring diagram for STP models and reiterates pre-lighting safety procedures.
STP Lighting and Shut-off
Electric Spark Ignition Procedure
Provides detailed steps for lighting the pilot and burner using the electric spark system.
Gas Shut-off and LP Warnings
Explains how to turn off the gas and reiterates critical safety warnings for LP propane users.
STP Model Troubleshooting
STP Ignition and Gas Supply Issues
Covers common ignition failures and gas supply problems for STP models, listing causes and fixes.
STP Troubleshooting Continued
STP Pilot Flame and Burner Issues
Discusses pilot flame stability, frequent outages, and main burner operation issues for STP models.
Replacement Parts
SF3624-TV Parts Identification
Lists all replacement parts for the SF3624-TV model with corresponding diagram numbers.
SF4224-TV Parts Identification
Lists all replacement parts for the SF4224-TV model with corresponding diagram numbers.
Two Year Limited Warranty
Warranty Coverage and Information
Explains warranty terms, coverage, conditions, and provides necessary information for claims.

Table of Contents