Note: Not intended for fireplace insert.
The clearances listed below are MINIMUM distances. Measure the clearance to both the appliance and the chimney connector.
(The farthest distance is correct if the two clearances do not coincide.) For example, if the appliance is set as indicated
in one of the figures but the connector is too close, move the stove until the correct clearance to the connector is obtained.
This unit can be installed on a solid combustible surface like a wood floor.This unit can also be installed directly on carpeting
or vinyl when the bottom pedestal cover plate (provided with unit) is installed.
This appliance may be installed only with the clearances as shown in the situations pictured. Do not combine clearances from
one type of installation with another in order to achieve closer clearances.
Use the minimum clearances shown in the diagrams below for installation with a standard 100mm flue.
F43-NG & F43-LP Clearances
F43-NG & F43-LP Clearances
F43-NG & F43-LP Clearances
F43-NG & F43-LP Clearances
F43-NG & F43-LP Clearances
A Side Wall to Unit
B Back Wall to Unit 6" / 155 mm
E Side Wall to Unit
F43-NG & F43-LP Reference Dimensions
F43-NG & F43-LP Reference Dimensions
F43-NG & F43-LP Reference Dimensions
F43-NG & F43-LP Reference Dimensions
F43-NG & F43-LP Reference Dimensions
C Back Wall to Flue Centerline
D Side Wall to Flue Centerline
F Side Wall to Flue Centerline
Minimum ceiling height is 36" / 914 mm from top of unit.
If further reduced clearances are needed, obtain requirements for construction of a protected wall from your local building
authorities and their allowable reductions of the listed clearances.
Masport F43/F28 Freestanding Gas Heater
CLEARANCES TO COMBUSTIBLES
7-1/2" / 190 mm
2" / 50 mm
10-1/2" / 265 mm
22-1/8" / 562 mm
11" / 280 mm
F28-NG & F28-LP Clearances
A Side Wall to Unit
B Back Wall to Unit 6" / 155 mm
E Side Wall to Unit
F28-NG & F28-LP Reference Dimensions
C Back Wall to Flue Centerline
D Side Wall to Flue Centerline
F Side Wall to Flue Centerline
INSTALLATION
7-1/2" / 190 mm
2" / 50 mm
10-3/4" / 273 mm
20-1/2" / 520 mm
11" / 280 mm