Advertisement

Uninterruptible Power Supply
ERA LED 0.65
ERA LED 0.85
ERA LED 1.1
User's manual

Advertisement

Table of Contents
loading

Summary of Contents for Tecnoware ERA LED 0.65

  • Page 1 Uninterruptible Power Supply ERA LED 0.65 ERA LED 0.85 ERA LED 1.1 User’s manual...
  • Page 3: Table Of Contents

    Edition: May 2012 – version: 1.0 No part of this manual may be reproduced, even partially, without the authorisation of TECNOWARE s.r.l. TECNOWARE s.r.l. reserves the right to change specifications at any time and without notice. UPS ERA LED 0.65 – 0.85 – 1.1...
  • Page 4: Safety Warnings

    Safety Warnings Read this manual carefully and completely before installing and using the TECNOWARE ERA LED Uninterruptible Power Supply, which, from here after, will also be referred to as UPS. This manual should be kept close to the UPS and read before the UPS is installed and used.
  • Page 5: Introduction

    • ERA LED 0.65 (650 VA) • ERA LED 0.85 (850 VA) • ERA LED 1.1 (1100 VA) In this manual ERA LED will simply be referred to as UPS. UPS ERA LED 0.65 – 0.85 – 1.1 User’s manual...
  • Page 6: General Characteristics

    Do not keep liquids, flammable gases or corrosive substances near the unit. • Install the UPS on a properly tiled floor. Avoid the installation on a floor that is not tiled flat. • User’s manual UPS ERA LED 0.65 – 0.85 – 1.1...
  • Page 7: External Description

    The LINE/BATTERY led: this led (blue color) is always on during the functioning in Normal Mode, it flashes one time every 4 seconds in Battery mode and it flashes one time every second in Low Battery condition. Figure 1 – Front panel UPS ERA LED 0.65 – 0.85 – 1.1 User’s manual...
  • Page 8: Rear Side

    Computer Interface (USB connector): it is the communication USB port. In case of anomaly to the AC line (black-out), the UPS Output receptacles (black colour, #3) continue supplying the correct power to all connected equipment. User’s manual UPS ERA LED 0.65 – 0.85 – 1.1...
  • Page 9: Electrical Installation And First Start Up

    There are no internal parts in the UPS that are user serviceable. Any repair or maintenance work must be performed exclusively by qualified technical personnel authorized by TECNOWARE. TECNOWARE declines any responsibility if this warning is disregarded. Disregard for these warnings may lead to a risk of electric shock to operators.
  • Page 10: Functioning

    After a complete discharge, the UPS needs 4 hours to recharge completely the batteries. The UPS recharges batteries automatically if it works in Normal mode or if it is off and connected to the AC Input Line. User’s manual UPS ERA LED 0.65 – 0.85 – 1.1...
  • Page 11: Load Control

    The USB signals are all isolated through photo-couplers from the dangerous voltages that are present inside the UPS. Connecting to the Web site www.tecnoware.com, it is possible to download, free of charge, the update UPS management Software ViewPower, compatible with the most popular Operative Systems.
  • Page 12: Technical Characteristics

    4 UPS Output sockets (IEC type) Dimension (W x H x D) 10,1 x 14,2 x 27,9 cm Net Weight 3.7 Kg 3.7 Kg 3.7 Kg Technical data may change without prior notice User’s manual UPS ERA LED 0.65 – 0.85 – 1.1...
  • Page 13: Maintenance

    Disconnect the battery wires and gently extract the battery from the case. The new battery must be exactly the same type as the original one. Put inside the new battery and connect it as the original one. Reassemble the case cover. UPS ERA LED 0.65 – 0.85 – 1.1 User’s manual...
  • Page 14: Operator Safety

    Battery replacement must be performed exclusively by qualified technical personnel authorized by TECNOWARE. TECNOWARE declines any responsibility if this warning is disregarded. When replacing batteries, replace with the same type and number. CAUTION: A battery can present a risk of electrical shock and high short circuit current.
  • Page 15 TECNOWARE. TECNOWARE declines any responsibility if this warning is disregarded. Warning to the technical personnel authorized for service: since internal components are connected to the batteries, they will remain powered, and therefore dangerous, even after the UPS has been disconnected from AC power mains.
  • Page 16: Conformity To The European Directives

    Conformity to the European Directives TECNOWARE S.r.l. confirms that ERA LED models comply with the requirements set out in: the Low Voltage Directive (Safety) 2006/95/EC and following amendments, the EMC (Electro-Magnetic Compatibility) Directive 2004/108/EC and following amendments. The following standards were applied:...
  • Page 19 TECNOWARE s.r.l. www.tecnoware.com...

Table of Contents