6
CyberDome II
Installation Manual
Cable requirements
Table 3 lists the requirements for the cables that connect to the dome.
Table 3.
Cable requirements
Operation
Data
Video
Alarm
Relay contacts
Power
Note: When using UTP cable for video and data, the wires can share the same jacket but must remain separate twisted pairs.
Power cable size and length requirements
Using the proper gauge of power cable will ensure proper operation and avoid voltage drops. See Table 4 for
the recommended cable gauge for varying maximum cable lengths and power draws.
Table 4.
Recommended power cable gauges based on maximum lengths for an operating voltage of 24 VAC (±4 VAC)
Wire gauge
AWG
mm (dia.)
10
2.60
12
2.05
14
1.62
16
1.29
18
1.02
WARNING: Be aware that the power requirements for CyberDome II and CyberDome are different, which may require
new cabling when replacing CyberDomes with CyberDome II domes.
Cable requirement
For RS-422: 22 gauge (0.64 mm) unshielded, two-conductor, twisted-pair (UTP)
cable
For RS-485: 22 gauge (0.64 mm) shielded, two-conductor, twisted-pair (STP) cable
75 ohm coaxial cable (RG59 with lift/gain)
22 gauge (0.64 mm) unshielded, two-conductor, twisted-pair (UTP) cable
Note: Use only crimp-on BNC connectors. Do not use screw-on connectors.
Cat-5 cable (recommended)
Cat-5 cable (recommended). Contacts rated for 60 W DC, 62.5 W AC with 2 A max.
24 VAC cable. To determine the size of cable needed for individual applications, see
length
requirements.
Domes with fan (20 VA)
feet
meters
1569
478
988
301
620
188
391
119
246
74
Domes with
12 W heater/fan (x2) (45 VA)
feet
meters
784
238
494
150
310
94
196
59
123
37
Length
feet
meters
10,000
3,000
3,000
900
1,600
486
1,250
381
1,250
381
1,250
381
Power cable size and
HD domes with
23 W heater/fan (x2) (66 VA)
feet
meters
490
149
309
94
194
59
122
37
77
23
Need help?