Filter Board

To remove the main fi lter board:
1.
Remove the induction module. (See
.)
Module
2.
Place the module component side down on a
protective surface.
3.
Note the location of the black, red, and green
wires and the 2 jumper blades connected to the
fi lter board power terminals.
4.
Remove the T-20 Torx screw and the wire
retainer from the module.
5.
Using a T-20 Torx or a fl at blade screwdriver,
loosen the 5 terminal screws, then remove the
black, red, and green wires, and the 2 jumper
blades.
6.
Tighten the terminal screws.
Wire Retainer
Jumper
Blade
Jumper
Blade
7. Place the module component side up on a
protective surface.
8. Mark the location, then disconnect the black L1,
blue L2, and ground wire connections on the
fi lter board.
9. Disconnect the thermal cut-out and fi lter-to-
Induction
bridge wire harnesses.
10. Disconnect the LINbus connectors. (See
Connectors
11. Using a fl at blade screwdriver, carefully press
the 2 left side large tabs away from the fi lter
board. Lift the fi lter board and pull the fi lter
board away from the smaller tab on the right
side of the module base.
Retainer
Tab
Screw
Arrows indicate disconnect locations
– 55 –
.)