Control Panel; Control Panel Assembly; Main Logic Board - GE Profile PHB925SB1SS Technical Service Manual

30-in. free standing induction range
Table of Contents

Advertisement

Control Panel

The control panel contains the main logic board and
the glass touch controls.
To remove the control panel:
1.
Pull the range out approximately 6 inches from
the wall.
2.
Place a protective cover on the main top.
3.
Remove the 2 Phillips-head screws that attach
the bottom of the control panel to the range.
4. Remove the two 1/4-in. hex-head screws that
attach the top of the control panel to the range.
Rear View
5. Carefully lower the control panel and place it
face down on the protective surface.
Service Position

Control Panel Assembly

Main Logic Board

The main logic board is located inside the control
panel. The main logic board is held to the control
panel with two screws at the top and 2 tabs at the
bottom. The glass touch panel assembly plugs into
the main logic board.
To remove the main logic board assembly:
1.
2.
3.
4. Tilt the top of the main logic board down and lift
Note: Before connecting power to the replacement
main logic board, transfer the model selector,
located at J201, to the replacement main logic
board. (See
– 47 –
Remove the control panel rear cover. (See
.)
Control Panel Rear Cover
Disconnect the range wire harnesses and the
touch panel ribbon connectors from the main
logic board assembly.
Remove the two 1/4-in. hex-head screws that
attach the top of the main logic board to the
control panel.
Disconnect
the main logic board from the control panel.
Control Boards Connector Locator Views
Disconnect
.)