GE Profile PHB925SB1SS Technical Service Manual page 51

30-in. free standing induction range
Table of Contents

Advertisement

Note: On the 11-in. element, the choke must be
removed and transferred to the replacement
element. The choke must be attached at the same
location on the wires and secured with a plastic wire
tie.
Plastic Wire Tie
Choke
Warming Zone Element
The warming zone element operates on
240 VAC.
The element is rated at 100 watts, has an
approximate resistance value of 550 Ω, and
draws approximately 0.43 amps.
Warming zone element operation is controlled
by RPSM duty cycling algorithms. See table
below.
SETTING
Hi
Med
Lo
TIME VOLTAGE APPLIED
79%
54%
30%
To remove the warming zone element:
1.
Remove the aluminum plate. (See
.)
Plate
2.
Place the aluminum plate element side up on a
protective surface.
3.
Disconnect the wires from the warming zone
element.
Note: The warming zone element is locked into
cutouts in the aluminum plate using 2 tabs. To
remove the element, it is necessary to fi rst position
the tab, located at the 2 o'clock position, into the
release notch.
4. Carefully grasp the outer portion of the element
and rotate it counterclockwise 1 inch until it
reaches the stop position, then lift the element
from the aluminum plate.
Disconnect
Note: The warming zone element is locked into
cutouts in the aluminum plate using 2 tabs. To
remove the element, it is necessary to fi rst position
the tab, located at the 2 o'clock position, into the
release notch.
4. Carefully grasp the outer portion of the element
and rotate it counterclockwise 1 inch until it
reaches the stop position, then lift the element
from the aluminum plate.
– 51 –
Aluminum
Tab
Notch