Yearly Service Procedure - Travis Industries 31 DVI GSB2 Owner's Manual

Direct vent fireplace insert
Table of Contents

Advertisement

30

Yearly Service Procedure

Failure to inspect and maintain the heater may lead to improper combustion and a potentially dangerous
situation. We recommend the following procedures be done by a qualified technician.
1.
Turn the pilot flame to continuous. It should touch approximately 3/8" of the top of the flame sensor. If it does
not, contact your dealer for service.
2.
Shut off gas to the heater and let it cool for 15 minutes. Remove the glass (see page 21). Glass may be
cleaned with glass cleaner and a soft cloth (do not use abrasive cleaners).
3.
Remove the media (see the instructions included with your media kit). If severely deteriorated, replace. Check
the media for sooting. A small amount of soot along the bottom of the media is normal. If excessive sooting is
found, the heater will require adjustment. Contact your dealer.
4.
Inspect the burner and remove any debris.
Make sure the burner is not warped, cracked, or damaged.
Check the firebox and area around the pilot to make sure there is no warping or damage.
If any problem is found, discontinue use and contact your dealer for service.
5.
Replace the media. Clean and replace the glass. If the glass is damaged, replace. Make sure the gasket along
the perimeter of the glass contacts the face of the firebox and forms an air-tight seal. If it does not, re-align or
replace the gasket to insure an air-tight seal.
6.
Inspect the area behind the access door. Clean if necessary. Check the gas
control valve and the gas lines. If damage is found, discontinue use and contact
your dealer for service. Clean the air channels, ducts, and blower (if applicable).
7.
Start the main burner. Inspect the main burner and pilot flame. After 15 minutes
the flames should be orange/yellow and not touch the top of the firebox. If the
pilot or main burners do not burn correctly, contact your dealer for service.
Monitor blower operation.
8.
Remove any debris or vegetation near the vent termination. Contact your dealer
if any sooting or deterioration is found near the vent termination. Venting system
should be examined by a qualified agency.
© Travis Industries