13.3. Capacity and power consumption

13.3.1. Cooling Performance
Model
CS-F24DB4E5
Cooling capacity
6.6kW
Ambient
Temperature Air Entering Condenser (°C D.B.)
Return
25°C
Air
TC
D.B.
W.B.
kW
17
6.87
23
19
7.26
22
7.92
17
6.79
25
19
7.26
22
7.92
17
6.71
27
19
7.27
22
7.91
17
6.69
29
19
7.26
22
7.88
17
6.68
32
19
7.25
22
7.86
TC: Cooling Capacity
Cooling capacities are based on conditions
Single phase, 50Hz 230V
Indoor temp. 27°C D.B. 19°C W.B.
Outdoor temp. 35°C D.B.
Standard air volume 18 m
30°C
35°C
40°C
TC
TC
TC
kW
kW
kW
6.60
6.21
5.74
7.03
6.67
6.22
7.71
7.36
6.88
6.53
6.15
5.70
7.01
6.64
6.18
7.68
7.30
6.80
6.45
6.09
5.66
7.00
6.60
6.14
7.65
7.25
6.73
6.45
6.07
5.70
7.00
6.60
6.19
7.61
7.20
6.74
6.45
5.64
5.73
7.00
6.60
6.22
7.59
7.19
6.75
3
/min
Ambient
43°C
Return
TC
Air
kW
D.B.
W.B.
5.41
17
5.90
23
19
6.56
22
5.38
17
5.86
25
19
6.50
22
5.35
17
5.81
27
19
6.44
22
5.42
17
5.88
29
19
6.43
22
5.46
17
5.93
32
19
6.43
22
IPT: Cooling Power Consumption
115
Temperature Air Entering Condenser (°C D.B.)
25°C
30°C
35°C
IPT
IPT
IPT
kW
kW
kW
2.00
2.16
2.36
2.12
2.29
2.50
2.29
2.48
2.70
2.00
2.16
2.35
2.13
2.30
2.50
2.30
2.48
2.70
2.00
2.16
2.35
2.14
2.31
2.51
2.31
2.49
2.71
1.99
2.15
2.32
2.13
2.30
2.48
2.34
2.54
2.73
1.98
2.15
2.30
2.12
2.30
2.46
2.36
2.57
2.75
40°C
43°C
IPT
IPT
kW
kW
2.59
2.74
2.74
2.91
2.96
3.14
2.57
2.72
2.73
2.90
2.95
3.13
2.55
2.71
2.73
2.89
2.95
3.12
2.49
2.60
2.66
2.78
2.93
3.06
2.45
2.53
2.62
2.70
2.92
3.01