Please file and use this manual together with the service manual for Model No. CS-F24DB4E5 CU- J24DBE5 CS-F24DB4E5 CU-J24DBE8 CS-F34DB4E5 CU-J34DBE5 CS-F34DB4E5 CU-J34DBE8 CS- F43DB4E5 CU-J43DBE8 CS-F50DB4E5 CU-J50DBE8, Order No. MAC0509062C2 and CS-F14DB4E5 CU- J14DBE5 CS-F18DB4E5 CU-J18DBE5, Order No. MAC0602017C2.
1 Features 1.1. Twin 1.1.1. Twin Operation • Simultaneous air conditioning of wide spaces and corners is possible. Indoor units with same horsepowers can even be used in combination. • Master unit and slave-units can be set automatically in twin systems. No address setting is necessary. •...
2 Product Specification 2.1. CS-F14DB4E5 CU-J28DBE5 ITEM / MODEL Indoor Unit Outdoor Unit CS-F14DB4E5 × 2 Main Body CU-J28DBE5 Panel CZ-BT03P Remote CZ-RD513C (Wired) Control CZ-RL513B (Wireless) Cooling Capacity 7.30 BTU/h 24,900 Refrigerant Charge-less Standard Air Volume for High, /min 2154 246 ×...
2.2. CS-F14DB4E5 CU-J28DBE8 ITEM / MODEL Indoor Unit Outdoor Unit CS-F14DB4E5 × 2 Main Body CU-J28DBE8 Panel CZ-BT03P Remote CZ-RD513C (Wired) Control CZ-RL513B (Wireless) Cooling Capacity BTU/h 24,900 Refrigerant Charge-less Standard Air Volume for High, /min 2154 246 × 840 × 840 795 ×...
Single Single Power Consumption Cooling 3.88 3.93 3.98 Running Current Cooling 17.8 18.1 18.4 Starting Current Power Factor Cooling *Power Factor means total figure of compressor, indoor fan motor and outdoor fan motor. Panasonic Power source AC, 1~220V,230V, 240V 50Hz...
Three Three Power Consumption Cooling 3.75 3.80 3.85 Running Current Cooling 6.10 6.20 6.30 Starting Current Power Factor Cooling *Power Factor means total figure of compressor, indoor fan motor and outdoor fan motor. Panasonic Power source AC, 3~380V,400V, 415V 50Hz...
Volts Phase Three Three Three Power Consumption Cooling 4.74 4.79 4.84 Running Current Cooling Starting Current Power Factor Cooling *Power Factor means total figure of compressor, indoor fan motor and outdoor fan motor. Panasonic Power source AC, 3~380V,400V, 415V 50Hz...
Volts Phase Three Three Three Power Consumption Cooling 5.13 5.18 5.23 Running Current Cooling Starting Current Power Factor Cooling *Power Factor means total figure of compressor, indoor fan motor and outdoor fan motor. Panasonic Power source AC, 3~380V,400V, 415V 50Hz...
4 Troubleshooting Guide 4.1. During twin operation System example 1. The main power is turned on while the transmission wires between the indoor units are not connected. (open circuit at A or B) Symptom Remote control unit: “check” flashes Error code: F30-01 (connected indoor capacity error) Indoor unit No.
Page 12
Indoor unit: LED1 on P.C.B flashes Outdoor unit: LED6, 7 on P.C.B flashes 4. The main power is turned on and the connection wire is all ok. If operation starts in this condition, combination of the B50DBE8 outdoor unit and F24DB4E5 indoor unit will result in abnormal operation.