15 CAPACITY AND POWER CONSUMPTION

15.1. HEATING PERFORMANCE
CS-W50BTP
CU-W50BBP8
Heating capacity 14.0 kW
3
Air Volume (m
35
H.C. = Heating Capacity
IPT = Power Consumption
Model
3 phase, 50Hz, 400V
Indoor temperature 20°C D.B.T.
Outdoor temperature 7°C D.B. 6°C W.B.T.
Standard air volume 35m
Inlet Air
/min)
Entering Air
D.B.T. (°C)
H.C.
15
11.68
20
11.04
25
10.40
Heating capacities are based on conditions below.
3
/min
Outdoor Temperature (°C W.B.T.)
-6°C
0°C
IPT
H.C.
IPT
3.82
14.00
4.36
4.03
13.20
4.63
4.25
12.48
4.91
35
6°C
12°C
H.C.
IPT
H.C.
16.8
5.18
19.5
16.0
5.45
19.2
15.2
5.72
18.4
IPT
6.10
6.32
6.52