Panasonic CS-F24DB4E5 Service Manual page 126

Air conditioner
Hide thumbs Also See for CS-F24DB4E5:
Table of Contents

Advertisement

Model
CS-F43DB4E5
Heating capacity
14.0kW
Ambient
Temperature Air Entering Condenser (°C D.B.)
Return
-6°C
Air
HC
D.B.
kW
15
10.22
20
9.66
25
9.10
HC: Heating Capacity
Heating capacities are based on conditions
3 phase, 50Hz 400V
Indoor temp. 20°C D.B.
Outdoor temp. 7°C D.B. 6°C W.B.
Standard air volume 31 m
0°C
6°C
12°C
HC
HC
HC
kW
kW
kW
12.25
14.70
17.08
11.55
14.00
16.80
10.92
13.30
16.10
3
/min
Ambient
Temperature Air Entering Condenser (°C D.B.)
Return
-6°C
Air
IPT
D.B.
kW
15
3.28
20
3.47
25
3.66
IPT: Heating Power Consumption
126
0°C
6°C
12°C
IPT
IPT
IPT
kW
kW
kW
3.75
4.46
5.25
3.99
4.69
5.44
4.22
4.92
5.56

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents