Tube Material
Outer Diameter
Thickness
Row
No. of Tubes/Row
Fin Material
Thickness
Fin Pitch
Fin Surface
Total Face Area
Fan Type
No.of /Unit
Fan Starting Method
Motor Rated Output
Poles
Phase
Insulation Class

15. CAPACITY AND POWER CONSUMPTION

15.1. HEATING PERFORMANCE
Model
Heating capacities are based on
conditions below.
CS-
A24BB4P
1 phase, 50Hz, 230V / Indoor
Heating
temperature 20°C D.B. / Outdoor
capacity 7.1
temperature 7°C D.B. 6°C W.B. /
kW
Standard air volume 17m
mm
9.52
mm
0.3
2
34
mm
0.105
NO./
14
inch
AX-Louvre
AX-Louvre
fin
0.61
m
2
1
kW
0.05
6
Single-
Phase
E
/min
3
81
Copper tube
9.52
9.52
0.3
2
34
Aluminium
0.105
0.105
14
AX-Louvre fin
fin
0.61
0.82
Propeller Fan
1
Direct on-line Starting
0.05
0.05 x 2
6
Single-
Single-Phase
Phase
E
9.52
0.3
0.3
2
2
46
46
0.105
14
14
AX-Louvre
fin
1.05
2
2
0.05 x 2
6
6
Single-
Phase
E
E
AX
0.055