Normal Control - Panasonic CS-F24DB4E5 Service Manual

Air conditioner
Hide thumbs Also See for CS-F24DB4E5:
Table of Contents

Advertisement

9.6.

Normal Control

9.6.1.
Cooling Indoor Fan Control
• Manual Fan Speed
Operation starts at High, Medium or Low speed set by remote control.
• Auto Fan Speed
When operation start, or shifting to thermostat ON condition from thermostat OFF condition, indoor fan operates as below.
Thermostat & Compres-
sor ON/OFF
Time
Cool
Auto
Soft Dry
Auto
9.6.2.
Heating Indoor Fan Control
• Manual Fan Speed
Operation starts at High, Medium or Low speed set by remote control.
However, when operation start, or during operation, fan speed control is limited due to prevent a cold draft, for example, when
heating operation start.
• Auto Fan Speed
When operation start, or shifting to thermostat ON condition from thermostat OFF condition, indoor fan operates as below.
• If thermostat is off, indoor fan fixed low speed; Louver angle fixed at upper limit, regardless remote control setting.
9.6.3.
Louver Control
• When power is on, at the same time, louver start initializing toward to close Direction.
• During operation, stopping, thermostat off condition, louver angle set manual or auto depend on remote controller setting.
Thermostat &
Compressor ON
40 sec.
50 sec.
-
Off
Lo
Hi
Off
Lo
Lo
Thermostat &
Compressor OFF
20 sec.
120 sec.
20 sec.
Lo
Off
Lo
Lo
Off
Lo
40
Thermostat &
Compressor ON
40 sec.
50 sec.
-
Off
Lo
Me
Off
Lo
Lo

Hide quick links: