3.8.

Safety Devices

INDOOR UNIT
Indoor Unit
For fan motor protection
Internal
protector (49F)
For condensation temperature
protection control Heater
exchanger thermistor
For control protection
Fuse
OUTDOOR UNIT
Heat
pump
Outdoor Unit
Model
For refrigerant cycle
High pressure
OFF
switch (63H1)
ON
Low pressure
switch
OFF
ON
For compressor
Over current protection
Heat Pump Model
OFF
Cooling only Model
OFF
RESET
Discharge temperature
protection
Discharge
Com-
temperature
thermistor (Th1)
pressor
OFF
Liquid compress
protection
Input
Crankcase heater
Power
Compressor
protection
Internal protector
OFF
ON
trip
time
For fan motor
protection
Internal
OFF
protector (49F)
ON
Heating control
(Heat Pump only)
Pressure switch
OFF
(Fan speed) (63H2)
ON
Cooling control
Heat exchanger
Control method
outlet temperature
thermistor (Th2)
For control protec-
tion
Fuse
CUT
2
1Mpa=10.2kgf/cm
Heat Pump Model
CS-F24DB4E5
Cooling only Model
°C
OFF
°C
ON
°C
OFF
°C
RESET
CUT
A
50Hz
CU-B24DBE5 CU-B28DBE5 CU-B28DBE8 CU-B34DBE5 CU-B34DBE8 CU-B43DBE8 CU-B50DBE8
4.15
4.15
Mpa
3.05
3.05
Mpa
_
Mpa
_
Mpa
A
19
20
A
-
Automatic
Automatic
°C
115
115
W
37
37
°C
160
165
°C
90
90
3-10sec/65A
3-10sec/78A
°C
135
135
°C
85
85
_
Mpa
_
Mpa
A
6.3
6.3
CS-F28DB4E5
135
135
86
86
58
58
54
54
3.15
3.15
4.15
4.15
3.05
3.05
_
_
-0.03
_
_
0.05
7.5
-
-
Automatic
Automatic
115
120
37
165
160
80
3-10sec/25A
135
135
85
_
_
_
_
Th 40°C ——— High speed
Th
40°C ——— 5 speed step control
6.3
16
CS-F34DB4E5
CS-F43DB4E5
135
135
86
86
58
58
54
54
3.15
3.15
4.15
3.05
-0.03
0.05
29
11
29
11
Automatic
Automatic
120
37
37
160
90
90
135
86
86
_
_
_
_
6.3
6.3
CS-F50DB4E5
135
86
58
54
3.15
4.15
4.15
3.05
3.05
-0.03
-0.03
0.05
0.05
14
15
14
15
Automatic
120
120
37
37
160
160
90
90
135
135
86
86
_
_
_
_
6.3
6.3

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents