9
SPECIFICATIONS AND SUPPLIED ACCESSORIES
Specifications
• Frequency coverage (MHz):
U.S.A. version
Non-U.S.A. versions
• Receive system
• Mode
• Frequency stability
• Frequency resolution
• Power supply
requirement
• Current drain (at 13.8 V DC):
Standby (software OFF)
Receive (squelched)
Receive (max. audio)
• Usable temp. range
• Intermediate frequencies:
1st
2nd
3rd
38
0.01–823.999,*
849.001–868.999, 894.001–1300
0.01–1300*
* Specifications guaranteed 0.5–1300 MHz only.
: Triple superheterodyne (AM/FM)
Double superheterodyne (WFM)
: FM, AM, WFM,
: ± 5 ppm at 1300 MHz
(0°C to +50°C;
32°F to +122°F)
: 1 kHz (minimum)
: 13.8 V DC ±15 % for receiver
unit; or, supplied AC adapter
(negative ground)
0.1 A
0.6 A
0.7 A
: 0°C to +50°C;
+32°F to +122°F
266.7 MHz
10.7 MHz
450 kHz (except WFM)
• Receive sensitivity (typical)*:
Frequency
AM
(MHz)
(10 dB S/N)
0.5–1.799
2.5 µV
1.8–27.999
1.8 µV
28–49.999
50–699.999
1.0 µV
700–1300
1.3 µV
* When 230 kHz (for WFM), 15 kHz (for FM) and 6 kHz (for AM)
passband widths are selected.
• Squelch sensitivity (threshold):
Frequency
AM
(MHz)
(10 dB S/N)
0.5–1.799
1.8 µV
1.8–27.999
0.89 µV
28–49.999
50–699.999
0.71 µV
700–1300
0.89 µV
FM
WFM
(12 dB SINAD)
(12 dB SINAD)
—
—
0.5 µV
0.32 µV
0.79 µV
0.4 µV
1.0 µV
FM
WFM
(12 dB SINAD)
(12 dB SINAD)
—
—
0.63 µV
0.5 µV
5.6 µV
0.63 µV
10 µV
Need help?
Do you have a question about the COMMUNICATION RECEIVER IC PCR100 and is the answer not in the manual?
Questions and answers